GENERIC revision 1.51
1# 2# Distribution kernel (NEC VR based model) kernel config file 3 4# 5# $NetBSD: GENERIC,v 1.51 2000/05/17 08:38:25 shin Exp $ 6# 7include "arch/hpcmips/conf/std.hpcmips" 8 9#ident "GENERIC-$Revision: 1.51 $" 10 11maxusers 8 12 13options MIPS3 # R4000/R4400/R4600 CPUs 14 15# Support for specific models of H/PC MIPS 16options VR41X1 # NEC VR41x1 series 17options MIPS3_4100 # VR4100 core 18options NOFPU # No FPU 19options SOFTFLOAT # emulate FPU insn 20options MIPS3_L2CACHE_ABSENT 21 22# Standard system options 23options DDB # in-kernel debugger 24#options DDB_ONPANIC=0 # don't enter debugger on panic 25#options DIAGNOSTIC # extra kernel debugging checks 26#options DEBUG # extra kernel debugging support 27options KTRACE # system call tracing support 28 29options SCSIVERBOSE # human readable SCSI error messages 30#options PCMCIAVERBOSE # verbose PCMCIA configuration messages 31 32#options RTC_OFFSET=0 # hardware clock is this many mins. west of GMT 33#options RTC_OFFSET=-540 # JST-9 34#options RTC_OFFSET=480 # PST8 35 # In NO RTC_OFFSET , inherit RTC_OFFSET 36 # from Windows CE. 37options NTP # network time protocol 38#options UCONSOLE # users can redirect console (unsafe) 39 40#options WINCE_DEFAULT_SETTING # Debugging use 41#options DUMP_GIU_LEVEL2_INTR # Debugging use 42#options DEBUG_FIND_PCIC # Debugging use XXX harmful don't define until read source. 43 44#options SYSCALL_DEBUG # for debug 45#options HPCMIPS_L1CACHE_DISABLE # disable L1 cache for debug 46#options HPCMIPS_FLUSHCACHE_XXX # for debug 47 48# Filesystem options 49file-system FFS # fast filesystem with user and group quotas 50file-system MFS # memory-based filesystem 51file-system NFS # Sun NFS-compatible filesystem (client) 52#file-system LFS # Log-based filesystem (still experimental) 53#file-system CD9660 # ISO 9660 + Rock Ridge file system 54file-system MSDOSFS # MS-DOS file system 55#file-system FDESC # /dev/fd 56file-system KERNFS # /kern (kernel informational filesystem) 57#file-system NULLFS # loopback file system 58#file-system OVERLAY # overlay file system 59#file-system PORTAL # portal filesystem (still experimental) 60file-system PROCFS # /proc 61#file-system UMAPFS # NULLFS + uid and gid remapping 62file-system UNION 63 64#options NFSSERVER # Sun NFS-compatible filesystem (server) 65#options SOFTDEP # FFS soft updates support. 66options QUOTA # UFS quotas 67 68# Pull in config fragments for kernel crypto. Use only one of these, 69# and adjust the prefixes as necessary. 70 71#prefix ../crypto-us/sys 72#cinclude "conf/files.crypto-us" 73#prefix 74 75#prefix ../crypto-intl/sys 76#cinclude "conf/files.crypto-intl" 77#prefix 78 79# Networking options 80#options GATEWAY # IP packet forwarding 81options INET # IP + ICMP + TCP + UDP 82options INET6 # IPV6 83#options IPSEC # IP security 84#options IPSEC_ESP # IP security (encryption part; define w/ IPSEC) 85#options IPSEC_DEBUG # debug for IP security 86#options MROUTING # Multicast routing support 87#options ISO # OSI networking 88#options TPIP # TPIP 89#options EON # OSI tunneling over IP 90#options CCITT,LLC,HDLC # X.25 91 92# NetBSD backwards compatibility 93options COMPAT_43 94 95options NFS_BOOT_DHCP 96 97config netbsd root on ? type ? 98 99# WS console uses SUN or VT100 terminal emulation 100options WSEMUL_VT100 101options WSDISPLAY_DEFAULTSCREENS=4 102#options FONT_VT220L8x8 103options FONT_VT220L8x10 104# compatibility to other console drivers 105options WSDISPLAY_COMPAT_PCVT # emulate some ioctls 106options WSDISPLAY_COMPAT_SYSCONS # emulate some ioctls 107options WSDISPLAY_COMPAT_USL # VT handling 108options WSDISPLAY_COMPAT_RAWKBD # can get raw scancodes 109 110vrip* at mainbus0 111vrcmu* at vrip? addr 0x0b000060 size 0x20 112vrbcu* at vrip? addr 0x0b000000 size 0x20 113vrrtc* at vrip? addr 0x0b0000c0 size 0x20 intr 2 114 115vrkiu* at vrip? addr 0x0b000180 size 0x20 intr 7 116options __NO_SOFT_SERIAL_INTERRUPT 117com* at vrip? addr 0x0c000000 size 0x20 intr 9 pwctl PWCTL_COM0 118vrgiu* at vrip? addr 0x0b000100 size 0x20 intr 8 119vrpmu* at vrip? addr 0x0b0000a0 size 0x20 intr 1 # power switch 120vrdsu* at vrip? addr 0x0b0000e0 size 0x08 121vrpiu* at vrip? addr 0x0b000120 size 0x1a0 intr 5 122 123# Workstation Console attachments 124bivideo0 at mainbus0 125hpcfb* at bivideo0 126wsdisplay* at hpcfb? 127wskbd* at vrkiu? mux 1 128wsmouse* at vrpiu? mux 0 129btnmgr0 at mainbus0 130wskbd* at btnmgr0 mux 1 131 132# 133# hpcmips isa? bus irq locator means: 134# 135# 0x0000000f ISA IRQ# 136# 0x00ff0000 GPIO port# 137# 0x01000000 interrupt signal hold/through (1:hold/0:though) 138# 0x02000000 interrupt detection level (1:low /0:high ) 139# 0x04000000 interrupt detection trigger (1:edge/0:level ) 140 141# 142# MC-R300, MC-R500 143# Button to GPIO port # mapping 144# + REC button : 4 145# + Open/Close button: 6 146# (PCIC-ISA : 9) 147# (COM power:14) 148# 149# MC-R510 150# Button to GPIO port # mapping 151# + Open/Close button: 3 152# (PCIC-ISA : 9) 153# (COM power:14) 154# 155# MC-R530 156# Button to GPIO port # mapping 157# + Open/Close button: 3 158# + Application button: 2 159# (PCIC-ISA : 9) 160# (COM power:14) 161# 162# MC-R700 163# Button to GPIO port # mapping 164# + Open/Close button: 3 165# (PCIC-ISA : 9) 166# (COM power:46) 167# 168# MC-CS 169# Button to GPIO port # mapping 170# (PCIC-ISA : 9) 171# (COM power:14) 172# 173# IBM WorkPad z50 174# Button to GPIO port # mapping 175# + REC button : 1 176# + Application button? : 2 177# (PCIC-ISA : 9) 178# 179button0 at vrgiu? platform NEC_MCR_3XX id BTN_REC port 4 180button1 at vrgiu? platform NEC_MCR_3XX id BTN_COVER port 6 181button0 at vrgiu? platform NEC_MCR_500 id BTN_REC port 4 182button1 at vrgiu? platform NEC_MCR_500 id BTN_COVER port 6 183button0 at vrgiu? platform NEC_MCR_510 id BTN_COVER port 3 184button0 at vrgiu? platform NEC_MCR_520 id BTN_COVER port 3 185button0 at vrgiu? platform NEC_MCR_530 id BTN_COVER port 3 186button1 at vrgiu? platform NEC_MCR_530 id BTN_APP0 port 2 187button0 at vrgiu? platform NEC_MCR_7XX id BTN_COVER port 3 188button0 at vrgiu? platform NEC_MCCS id BTN_LIGHT port 8 189button0 at vrgiu? platform IBM_WORKPAD id BTN_REC port 1 active 0 190button1 at vrgiu? platform IBM_WORKPAD id BTN_APP0 port 2 active 0 191pwctl0 at vrgiu? platform NEC_MCR_3XX id PWCTL_COM0 port 14 192pwctl1 at vrgiu? platform NEC_MCR_300 id PWCTL_LCDLIGHT port 45 193pwctl2 at vrgiu? platform NEC_MCR_300 id PWCTL_LCD port 10 194pwctl0 at vrgiu? platform NEC_MCR_5XX id PWCTL_COM0 port 14 195pwctl0 at vrgiu? platform NEC_MCR_7XX id PWCTL_COM0 port 46 196pwctl0 at vrgiu? platform NEC_MCCS id PWCTL_COM0 port 14 197pwctl1 at vrgiu? platform NEC_MCCS id PWCTL_LCDLIGHT port 45 198pwctl2 at vrgiu? platform NEC_MCCS id PWCTL_LCD port 10 199vrisab0 at vrgiu? platform NEC_MCR 200vrisab0 at vrgiu? platform NEC_MCCS 201vrisab0 at vrgiu? platform IBM_WORKPAD isaportoffset 0x1000000 202isa0 at vrisab0 203pcic0 at isa0 port 0x3e0 iomem 0x70000 iosiz 0x4000 irq 0x00090003 204# 205# Freestyle 206# Button to GPIO port # mapping 207# +---------+ 208# 1 +| | 209# | |+ 7 210# | | 211#20 +| LCD |+ 4 212# | | + 6 213# 8 +| |+ 5 214# | | 215# | |+----Power On/Off (connected to PMU) 216# +---------+ 217# +9 218# +12 +10 219# +11 220# (PCIC-ISA : 23) 221button0 at vrgiu? platform EVEREX_FREESTYLE id BTN_APP0 port 9 222button1 at vrgiu? platform EVEREX_FREESTYLE id BTN_APP1 port 10 223button2 at vrgiu? platform EVEREX_FREESTYLE id BTN_APP2 port 11 224button3 at vrgiu? platform EVEREX_FREESTYLE id BTN_APP3 port 12 225button4 at vrgiu? platform EVEREX_FREESTYLE id BTN_CANCEL port 7 226button5 at vrgiu? platform EVEREX_FREESTYLE id BTN_UP port 4 227button6 at vrgiu? platform EVEREX_FREESTYLE id BTN_OK port 6 228button7 at vrgiu? platform EVEREX_FREESTYLE id BTN_DOWN port 5 229button8 at vrgiu? platform EVEREX_FREESTYLE id BTN_REC port 1 230button9 at vrgiu? platform EVEREX_FREESTYLE id BTN_LIGHT port 20 231button10 at vrgiu? platform EVEREX_FREESTYLE id BTN_CONTRAST port 8 232vrisab1 at vrgiu? platform EVEREX_FREESTYLE isaportoffset 0x1000000 233isa1 at vrisab1 234pcic0 at isa1 port 0x3e0 iomem 0x70000 iosiz 0x4000 irq 0x00170003 235 236options PCIC_ISA_INTR_ALLOC_MASK=0x0008 # IRQ 3 only (MCR/Freestyle) 237 238# 239# Fujitsu INTERTOP CX300 240# 241pwctl0 at vrgiu? platform FUJITSU_INTERTOP id PWCTL_COM0 port 15 242vrisab2 at vrgiu? platform FUJITSU_INTERTOP isaportoffset 0x1000000 243isa2 at vrisab2 244pcic0 at isa2 port 0x3e0 iomem 0x70000 iosiz 0x4000 irq 0x00060003 245 246# 247# Vadem Clio and Sharp Tripad 248# 249vrisab3 at vrgiu? platform SHARP_TRIPAD isaportoffset 0x1000000 250isa3 at vrisab3 251pcic0 at isa3 port 0x3e0 iomem 0x70000 iosiz 0x4000 irq 0x000d0003 252 253# 254# CASIO CASSIOPEIA E55 and for DoCoMo 255# 256button0 at vrgiu? platform CASIO_CASSIOPEIAE_E55 id BTN_OK active 0 port 6 257button1 at vrgiu? platform CASIO_CASSIOPEIAE_E55 id BTN_CANCEL active 0 port 7 258button2 at vrgiu? platform CASIO_CASSIOPEIAE_E55 id BTN_APP0 active 0 port 8 259button3 at vrgiu? platform CASIO_CASSIOPEIAE_E55 id BTN_APP1 active 0 port 9 260button4 at vrgiu? platform CASIO_CASSIOPEIAE_E55 id BTN_APP2 active 0 port 10 261button5 at vrgiu? platform CASIO_CASSIOPEIAE_E55 id BTN_APP3 active 0 port 11 262button6 at vrgiu? platform CASIO_CASSIOPEIAE_E55 id BTN_DOWN active 0 port 12 263button7 at vrgiu? platform CASIO_CASSIOPEIAE_E55 id BTN_UP active 0 port 13 264pwctl0 at vrgiu? platform CASIO_CASSIOPEIAE_E55 id PWCTL_COM0 port 38 265pwctl1 at vrgiu? platform CASIO_CASSIOPEIAE_E55 id PWCTL_LCDLIGHT port 26 266vrisab4 at vrgiu? platform CASIO_CASSIOPEIAE_E55 isaportoffset 0xc000 267isa4 at vrisab4 268wdc0 at isa4 port 0x170 irq 0x02000003 flags 0x0010 # AT_POLL 269 270# 271# Unknown machines 272# 273vrisab4 at vrgiu? 274isa4 at vrisab4 275 276# PCMCIA bus support 277pcmcia* at pcic? controller 0 socket ? 278 279# PCMCIA IDE disk 280wdc* at pcmcia? function ? 281wd* at wdc? channel ? drive ? flags 0x0000 282 283# PCMCIA network interfaces 284ep* at pcmcia? function ? # 3Com 3c589 and 3c562 Ethernet 285mbe* at pcmcia? function ? # MB8696x based Ethernet 286ne* at pcmcia? function ? # NE2000-compatible Ethernet 287sm* at pcmcia? function ? # Megahertz Ethernet 288wi* at pcmcia? function ? # Lucent WaveLan IEEE (802.11) 289awi* at pcmcia? function ? # WLI-PCM 290 291# PCMCIA Serial interfaces 292com* at pcmcia? function ? # Modems and serial cards 293 294# PCMCIA SCSI interfaces 295aic* at pcmcia? function ? 296esp* at pcmcia? function ? # NCR53c406 SCSI 297 298# ATAPI bus support 299atapibus* at wdc? channel ? 300cd* at atapibus? drive ? flags 0x0000 # ATAPI CD-ROM drives 301sd* at atapibus? drive ? flags 0x0000 # ATAPI disk drives 302 303# SCSI bus support 304scsibus* at aic? 305scsibus* at esp? 306sd* at scsibus? target ? lun ? # SCSI disk drives 307cd* at scsibus? target ? lun ? # SCSI CD-ROM drives 308 309pseudo-device loop 1 # network loopback 310pseudo-device ppp 2 # serial-line IP ports 311pseudo-device pty 64 # pseudo ptys 312pseudo-device bpfilter 16 # packet filter ports 313pseudo-device ipfilter # IP filter, NAT 314 315pseudo-device vnd 4 # virtual disk ick 316pseudo-device ccd 4 # concatenated disks 317pseudo-device rnd # /dev/random and in-kernel generator 318 319pseudo-device biconsdev 1 # build-in console device 320pseudo-device wsmux 2 # mouse & keyboard multiplexor 321#pseudo-device md 1 # memory disk device (ramdisk) 322 323#pseudo-device raid 4 # RAIDframe disk driver 324#options RAID_AUTOCONFIG # auto-configuration of RAID components 325 326# for IPv6 327pseudo-device gif 4 # IPv[46] over IPv[46] tunnel (RFC1933) 328#pseudo-device faith 1 # IPv[46] tcp relay translation i/f 329#pseudo-device stf 1 # 6to4 IPv6 over IPv4 encapsulation 330