Copyright (c) 2000 Matthew Jacob
All rights reserved.

Redistribution and use in source and binary forms, with or without
modification, are permitted provided that the following conditions
are met:
1. Redistributions of source code must retain the above copyright
notice, this list of conditions, and the following disclaimer,
without modification, immediately at the beginning of the file.
2. The name of the author may not be used to endorse or promote products
derived from this software without specific prior written permission.

Alternatively, this software may be distributed under the terms of the
the GNU Public License ("GPL").

THIS SOFTWARE IS PROVIDED BY THE AUTHOR AND CONTRIBUTORS ``AS IS'' AND
ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE
IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
ARE DISCLAIMED. IN NO EVENT SHALL THE AUTHOR OR CONTRIBUTORS BE LIABLE FOR
ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL
DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS
OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION)
HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT
LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY
OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF
SUCH DAMAGE.

Matthew Jacob
Feral Software
mjacob@feral.com

$FreeBSD$

.Dd November 5, 2012 .Dt SESD 8 .Os .Sh NAME .Nm sesd .Nd monitor SCSI Environmental Services Devices .Sh SYNOPSIS .Nm .Op Fl c .Op Fl d .Op Fl t Ar poll-interval .Ar device .Op Ar device ... .Sh DESCRIPTION .Nm monitors SCSI Environmental Services (or SAF-TE) devices for changes in state and logs such changes to the system error logger (see .Xr syslogd 8 ) . At least one device must be specified. When no other options are supplied, .Nm detached becomes a daemon, by default waking up every 30 seconds to poll each device for a change in state.

p The following options may be used: l -tag -width Ds t Fl c Try to clear enclosure status after read. t Fl t Ar poll-interval Change the interval of polling from the default 30 seconds to the number of seconds specified. t Fl d Instead of detaching and becoming a daemon, stay attached to the controlling terminal and log changes there as well as via the system logger. .El

p The user may then use .Xr getencstat 8 to get more detailed information about the state of the over enclosure device or objects within the enclosure device. .Sh FILES l -tag -width /dev/sesN -compact t Pa /dev/sesN SCSI Environmental Services Devices .El .Sh SEE ALSO .Xr ses 4 , .Xr getencstat 8 , .Xr setencstat 8 , .Xr setobjstat 8 , .Xr syslogd 8 .Sh BUGS This is something of a toy, but it is better than nothing.