Searched refs:I_DIRTY_DATASYNC (Results 1 - 16 of 16) sorted by last modified time

/netgear-WNDR4500v2-V1.0.0.60_1.0.38/src/linux/linux-2.6/fs/afs/
H A Dwrite.c646 __mark_inode_dirty(inode, I_DIRTY_DATASYNC);
/netgear-WNDR4500v2-V1.0.0.60_1.0.38/src/linux/linux-2.6/fs/ext2/
H A Dfsync.c43 if (datasync && !(inode->i_state & I_DIRTY_DATASYNC))
/netgear-WNDR4500v2-V1.0.0.60_1.0.38/src/linux/linux-2.6/fs/ext3/
H A Dfsync.c79 if (inode->i_state & (I_DIRTY_SYNC|I_DIRTY_DATASYNC)) {
/netgear-WNDR4500v2-V1.0.0.60_1.0.38/src/linux/linux-2.6/fs/ext4/
H A Dfsync.c79 if (inode->i_state & (I_DIRTY_SYNC|I_DIRTY_DATASYNC)) {
/netgear-WNDR4500v2-V1.0.0.60_1.0.38/src/linux/linux-2.6/fs/ntfs/
H A Dmft.c376 * NOTE: We only set I_DIRTY_SYNC and I_DIRTY_DATASYNC (and not I_DIRTY_PAGES)
381 * other hand, is not sufficient, because I_DIRTY_DATASYNC needs to be set to
384 * even though the vfs inode has the O_SYNC flag set. Also, I_DIRTY_DATASYNC
403 __mark_inode_dirty(VFS_I(base_ni), I_DIRTY_SYNC | I_DIRTY_DATASYNC); local
/netgear-WNDR4500v2-V1.0.0.60_1.0.38/src/linux/linux-2.6/fs/sysv/
H A Dfile.c46 if (datasync && !(inode->i_state & I_DIRTY_DATASYNC))
/netgear-WNDR4500v2-V1.0.0.60_1.0.38/src/linux/linux-2.6/fs/udf/
H A Dfsync.c45 if (datasync && !(inode->i_state & I_DIRTY_DATASYNC))
/netgear-WNDR4500v2-V1.0.0.60_1.0.38/src/linux/linux-2.6/fs/ufs/
H A Dfile.c39 if (datasync && !(inode->i_state & I_DIRTY_DATASYNC))
/netgear-WNDR4500v2-V1.0.0.60_1.0.38/src/linux/linux-2.6/fs/
H A Dfs-writeback.c62 if (flags & (I_DIRTY_SYNC | I_DIRTY_DATASYNC)) {
173 if (dirty & (I_DIRTY_SYNC | I_DIRTY_DATASYNC)) {
621 ((what & OSYNC_INODE) || (inode->i_state & I_DIRTY_DATASYNC)))
/netgear-WNDR4500v2-V1.0.0.60_1.0.38/src/linux/linux-2.6/fs/gfs2/
H A Dops_file.c472 int sync_state = inode->i_state & (I_DIRTY_SYNC|I_DIRTY_DATASYNC);
/netgear-WNDR4500v2-V1.0.0.60_1.0.38/src/linux/linux-2.6/fs/jffs2/
H A Dfs.c341 if (!(inode->i_state & I_DIRTY_DATASYNC)) {
/netgear-WNDR4500v2-V1.0.0.60_1.0.38/src/linux/linux-2.6/fs/jfs/
H A Dfile.c35 (datasync && !(inode->i_state & I_DIRTY_DATASYNC))) {
/netgear-WNDR4500v2-V1.0.0.60_1.0.38/src/linux/linux-2.6/fs/minix/
H A Dfile.c42 if (datasync && !(inode->i_state & I_DIRTY_DATASYNC))
/netgear-WNDR4500v2-V1.0.0.60_1.0.38/src/linux/linux-2.6/fs/nfs/
H A Dinode.c77 __mark_inode_dirty(inode, I_DIRTY_DATASYNC);
H A Dwrite.c469 __mark_inode_dirty(inode, I_DIRTY_DATASYNC);
/netgear-WNDR4500v2-V1.0.0.60_1.0.38/src/linux/linux-2.6/include/linux/
H A Dfs.h1182 #define I_DIRTY_DATASYNC 2 /* Data-related inode changes pending */ macro
1191 #define I_DIRTY (I_DIRTY_SYNC | I_DIRTY_DATASYNC | I_DIRTY_PAGES)

Completed in 284 milliseconds