d678a59d |
|
18-May-2024 |
Tom Rini <trini@konsulko.com> |
Revert "Merge patch series "arm: dts: am62-beagleplay: Fix Beagleplay Ethernet"" When bringing in the series 'arm: dts: am62-beagleplay: Fix Beagleplay Ethernet"' I failed to notice that b4 noticed it was based on next and so took that as the base commit and merged that part of next to master. This reverts commit c8ffd1356d42223cbb8c86280a083cc3c93e6426, reversing changes made to 2ee6f3a5f7550de3599faef9704e166e5dcace35. Reported-by: Jonas Karlman <jonas@kwiboo.se> Signed-off-by: Tom Rini <trini@konsulko.com>
|
#
7938ac65 |
|
01-May-2024 |
Tom Rini <trini@konsulko.com> |
mmc: Remove <common.h> and add needed includes Remove <common.h> from this driver directory and when needed add missing include files directly. Reviewed-by: Jaehoon Chung <jh80.chung@samsung.com> Reviewed-by: Peter Robinson <pbrobinson@gmail.com> Signed-off-by: Tom Rini <trini@konsulko.com>
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
d678a59d |
|
18-May-2024 |
Tom Rini <trini@konsulko.com> |
Revert "Merge patch series "arm: dts: am62-beagleplay: Fix Beagleplay Ethernet"" When bringing in the series 'arm: dts: am62-beagleplay: Fix Beagleplay Ethernet"' I failed to notice that b4 noticed it was based on next and so took that as the base commit and merged that part of next to master. This reverts commit c8ffd1356d42223cbb8c86280a083cc3c93e6426, reversing changes made to 2ee6f3a5f7550de3599faef9704e166e5dcace35. Reported-by: Jonas Karlman <jonas@kwiboo.se> Signed-off-by: Tom Rini <trini@konsulko.com>
|
#
7938ac65 |
|
01-May-2024 |
Tom Rini <trini@konsulko.com> |
mmc: Remove <common.h> and add needed includes Remove <common.h> from this driver directory and when needed add missing include files directly. Reviewed-by: Jaehoon Chung <jh80.chung@samsung.com> Reviewed-by: Peter Robinson <pbrobinson@gmail.com> Signed-off-by: Tom Rini <trini@konsulko.com>
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
d678a59d |
|
18-May-2024 |
Tom Rini <trini@konsulko.com> |
Revert "Merge patch series "arm: dts: am62-beagleplay: Fix Beagleplay Ethernet"" When bringing in the series 'arm: dts: am62-beagleplay: Fix Beagleplay Ethernet"' I failed to notice that b4 noticed it was based on next and so took that as the base commit and merged that part of next to master. This reverts commit c8ffd1356d42223cbb8c86280a083cc3c93e6426, reversing changes made to 2ee6f3a5f7550de3599faef9704e166e5dcace35. Reported-by: Jonas Karlman <jonas@kwiboo.se> Signed-off-by: Tom Rini <trini@konsulko.com>
|
#
7938ac65 |
|
01-May-2024 |
Tom Rini <trini@konsulko.com> |
mmc: Remove <common.h> and add needed includes Remove <common.h> from this driver directory and when needed add missing include files directly. Reviewed-by: Jaehoon Chung <jh80.chung@samsung.com> Reviewed-by: Peter Robinson <pbrobinson@gmail.com> Signed-off-by: Tom Rini <trini@konsulko.com>
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
d678a59d |
|
18-May-2024 |
Tom Rini <trini@konsulko.com> |
Revert "Merge patch series "arm: dts: am62-beagleplay: Fix Beagleplay Ethernet"" When bringing in the series 'arm: dts: am62-beagleplay: Fix Beagleplay Ethernet"' I failed to notice that b4 noticed it was based on next and so took that as the base commit and merged that part of next to master. This reverts commit c8ffd1356d42223cbb8c86280a083cc3c93e6426, reversing changes made to 2ee6f3a5f7550de3599faef9704e166e5dcace35. Reported-by: Jonas Karlman <jonas@kwiboo.se> Signed-off-by: Tom Rini <trini@konsulko.com>
|
#
7938ac65 |
|
01-May-2024 |
Tom Rini <trini@konsulko.com> |
mmc: Remove <common.h> and add needed includes Remove <common.h> from this driver directory and when needed add missing include files directly. Reviewed-by: Jaehoon Chung <jh80.chung@samsung.com> Reviewed-by: Peter Robinson <pbrobinson@gmail.com> Signed-off-by: Tom Rini <trini@konsulko.com>
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
d678a59d |
|
18-May-2024 |
Tom Rini <trini@konsulko.com> |
Revert "Merge patch series "arm: dts: am62-beagleplay: Fix Beagleplay Ethernet"" When bringing in the series 'arm: dts: am62-beagleplay: Fix Beagleplay Ethernet"' I failed to notice that b4 noticed it was based on next and so took that as the base commit and merged that part of next to master. This reverts commit c8ffd1356d42223cbb8c86280a083cc3c93e6426, reversing changes made to 2ee6f3a5f7550de3599faef9704e166e5dcace35. Reported-by: Jonas Karlman <jonas@kwiboo.se> Signed-off-by: Tom Rini <trini@konsulko.com>
|
#
7938ac65 |
|
01-May-2024 |
Tom Rini <trini@konsulko.com> |
mmc: Remove <common.h> and add needed includes Remove <common.h> from this driver directory and when needed add missing include files directly. Reviewed-by: Jaehoon Chung <jh80.chung@samsung.com> Reviewed-by: Peter Robinson <pbrobinson@gmail.com> Signed-off-by: Tom Rini <trini@konsulko.com>
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
d678a59d |
|
18-May-2024 |
Tom Rini <trini@konsulko.com> |
Revert "Merge patch series "arm: dts: am62-beagleplay: Fix Beagleplay Ethernet"" When bringing in the series 'arm: dts: am62-beagleplay: Fix Beagleplay Ethernet"' I failed to notice that b4 noticed it was based on next and so took that as the base commit and merged that part of next to master. This reverts commit c8ffd1356d42223cbb8c86280a083cc3c93e6426, reversing changes made to 2ee6f3a5f7550de3599faef9704e166e5dcace35. Reported-by: Jonas Karlman <jonas@kwiboo.se> Signed-off-by: Tom Rini <trini@konsulko.com>
|
#
7938ac65 |
|
01-May-2024 |
Tom Rini <trini@konsulko.com> |
mmc: Remove <common.h> and add needed includes Remove <common.h> from this driver directory and when needed add missing include files directly. Reviewed-by: Jaehoon Chung <jh80.chung@samsung.com> Reviewed-by: Peter Robinson <pbrobinson@gmail.com> Signed-off-by: Tom Rini <trini@konsulko.com>
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
d678a59d |
|
18-May-2024 |
Tom Rini <trini@konsulko.com> |
Revert "Merge patch series "arm: dts: am62-beagleplay: Fix Beagleplay Ethernet"" When bringing in the series 'arm: dts: am62-beagleplay: Fix Beagleplay Ethernet"' I failed to notice that b4 noticed it was based on next and so took that as the base commit and merged that part of next to master. This reverts commit c8ffd1356d42223cbb8c86280a083cc3c93e6426, reversing changes made to 2ee6f3a5f7550de3599faef9704e166e5dcace35. Reported-by: Jonas Karlman <jonas@kwiboo.se> Signed-off-by: Tom Rini <trini@konsulko.com>
|
#
7938ac65 |
|
01-May-2024 |
Tom Rini <trini@konsulko.com> |
mmc: Remove <common.h> and add needed includes Remove <common.h> from this driver directory and when needed add missing include files directly. Reviewed-by: Jaehoon Chung <jh80.chung@samsung.com> Reviewed-by: Peter Robinson <pbrobinson@gmail.com> Signed-off-by: Tom Rini <trini@konsulko.com>
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
d678a59d |
|
18-May-2024 |
Tom Rini <trini@konsulko.com> |
Revert "Merge patch series "arm: dts: am62-beagleplay: Fix Beagleplay Ethernet"" When bringing in the series 'arm: dts: am62-beagleplay: Fix Beagleplay Ethernet"' I failed to notice that b4 noticed it was based on next and so took that as the base commit and merged that part of next to master. This reverts commit c8ffd1356d42223cbb8c86280a083cc3c93e6426, reversing changes made to 2ee6f3a5f7550de3599faef9704e166e5dcace35. Reported-by: Jonas Karlman <jonas@kwiboo.se> Signed-off-by: Tom Rini <trini@konsulko.com>
|
#
7938ac65 |
|
01-May-2024 |
Tom Rini <trini@konsulko.com> |
mmc: Remove <common.h> and add needed includes Remove <common.h> from this driver directory and when needed add missing include files directly. Reviewed-by: Jaehoon Chung <jh80.chung@samsung.com> Reviewed-by: Peter Robinson <pbrobinson@gmail.com> Signed-off-by: Tom Rini <trini@konsulko.com>
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
d678a59d |
|
18-May-2024 |
Tom Rini <trini@konsulko.com> |
Revert "Merge patch series "arm: dts: am62-beagleplay: Fix Beagleplay Ethernet"" When bringing in the series 'arm: dts: am62-beagleplay: Fix Beagleplay Ethernet"' I failed to notice that b4 noticed it was based on next and so took that as the base commit and merged that part of next to master. This reverts commit c8ffd1356d42223cbb8c86280a083cc3c93e6426, reversing changes made to 2ee6f3a5f7550de3599faef9704e166e5dcace35. Reported-by: Jonas Karlman <jonas@kwiboo.se> Signed-off-by: Tom Rini <trini@konsulko.com>
|
#
7938ac65 |
|
01-May-2024 |
Tom Rini <trini@konsulko.com> |
mmc: Remove <common.h> and add needed includes Remove <common.h> from this driver directory and when needed add missing include files directly. Reviewed-by: Jaehoon Chung <jh80.chung@samsung.com> Reviewed-by: Peter Robinson <pbrobinson@gmail.com> Signed-off-by: Tom Rini <trini@konsulko.com>
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
d678a59d |
|
18-May-2024 |
Tom Rini <trini@konsulko.com> |
Revert "Merge patch series "arm: dts: am62-beagleplay: Fix Beagleplay Ethernet"" When bringing in the series 'arm: dts: am62-beagleplay: Fix Beagleplay Ethernet"' I failed to notice that b4 noticed it was based on next and so took that as the base commit and merged that part of next to master. This reverts commit c8ffd1356d42223cbb8c86280a083cc3c93e6426, reversing changes made to 2ee6f3a5f7550de3599faef9704e166e5dcace35. Reported-by: Jonas Karlman <jonas@kwiboo.se> Signed-off-by: Tom Rini <trini@konsulko.com>
|
#
7938ac65 |
|
01-May-2024 |
Tom Rini <trini@konsulko.com> |
mmc: Remove <common.h> and add needed includes Remove <common.h> from this driver directory and when needed add missing include files directly. Reviewed-by: Jaehoon Chung <jh80.chung@samsung.com> Reviewed-by: Peter Robinson <pbrobinson@gmail.com> Signed-off-by: Tom Rini <trini@konsulko.com>
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
d678a59d |
|
18-May-2024 |
Tom Rini <trini@konsulko.com> |
Revert "Merge patch series "arm: dts: am62-beagleplay: Fix Beagleplay Ethernet"" When bringing in the series 'arm: dts: am62-beagleplay: Fix Beagleplay Ethernet"' I failed to notice that b4 noticed it was based on next and so took that as the base commit and merged that part of next to master. This reverts commit c8ffd1356d42223cbb8c86280a083cc3c93e6426, reversing changes made to 2ee6f3a5f7550de3599faef9704e166e5dcace35. Reported-by: Jonas Karlman <jonas@kwiboo.se> Signed-off-by: Tom Rini <trini@konsulko.com>
|
#
7938ac65 |
|
01-May-2024 |
Tom Rini <trini@konsulko.com> |
mmc: Remove <common.h> and add needed includes Remove <common.h> from this driver directory and when needed add missing include files directly. Reviewed-by: Jaehoon Chung <jh80.chung@samsung.com> Reviewed-by: Peter Robinson <pbrobinson@gmail.com> Signed-off-by: Tom Rini <trini@konsulko.com>
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
d678a59d |
|
18-May-2024 |
Tom Rini <trini@konsulko.com> |
Revert "Merge patch series "arm: dts: am62-beagleplay: Fix Beagleplay Ethernet"" When bringing in the series 'arm: dts: am62-beagleplay: Fix Beagleplay Ethernet"' I failed to notice that b4 noticed it was based on next and so took that as the base commit and merged that part of next to master. This reverts commit c8ffd1356d42223cbb8c86280a083cc3c93e6426, reversing changes made to 2ee6f3a5f7550de3599faef9704e166e5dcace35. Reported-by: Jonas Karlman <jonas@kwiboo.se> Signed-off-by: Tom Rini <trini@konsulko.com>
|
#
7938ac65 |
|
01-May-2024 |
Tom Rini <trini@konsulko.com> |
mmc: Remove <common.h> and add needed includes Remove <common.h> from this driver directory and when needed add missing include files directly. Reviewed-by: Jaehoon Chung <jh80.chung@samsung.com> Reviewed-by: Peter Robinson <pbrobinson@gmail.com> Signed-off-by: Tom Rini <trini@konsulko.com>
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
d678a59d |
|
18-May-2024 |
Tom Rini <trini@konsulko.com> |
Revert "Merge patch series "arm: dts: am62-beagleplay: Fix Beagleplay Ethernet"" When bringing in the series 'arm: dts: am62-beagleplay: Fix Beagleplay Ethernet"' I failed to notice that b4 noticed it was based on next and so took that as the base commit and merged that part of next to master. This reverts commit c8ffd1356d42223cbb8c86280a083cc3c93e6426, reversing changes made to 2ee6f3a5f7550de3599faef9704e166e5dcace35. Reported-by: Jonas Karlman <jonas@kwiboo.se> Signed-off-by: Tom Rini <trini@konsulko.com>
|
#
7938ac65 |
|
01-May-2024 |
Tom Rini <trini@konsulko.com> |
mmc: Remove <common.h> and add needed includes Remove <common.h> from this driver directory and when needed add missing include files directly. Reviewed-by: Jaehoon Chung <jh80.chung@samsung.com> Reviewed-by: Peter Robinson <pbrobinson@gmail.com> Signed-off-by: Tom Rini <trini@konsulko.com>
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
d678a59d |
|
18-May-2024 |
Tom Rini <trini@konsulko.com> |
Revert "Merge patch series "arm: dts: am62-beagleplay: Fix Beagleplay Ethernet"" When bringing in the series 'arm: dts: am62-beagleplay: Fix Beagleplay Ethernet"' I failed to notice that b4 noticed it was based on next and so took that as the base commit and merged that part of next to master. This reverts commit c8ffd1356d42223cbb8c86280a083cc3c93e6426, reversing changes made to 2ee6f3a5f7550de3599faef9704e166e5dcace35. Reported-by: Jonas Karlman <jonas@kwiboo.se> Signed-off-by: Tom Rini <trini@konsulko.com>
|
#
7938ac65 |
|
01-May-2024 |
Tom Rini <trini@konsulko.com> |
mmc: Remove <common.h> and add needed includes Remove <common.h> from this driver directory and when needed add missing include files directly. Reviewed-by: Jaehoon Chung <jh80.chung@samsung.com> Reviewed-by: Peter Robinson <pbrobinson@gmail.com> Signed-off-by: Tom Rini <trini@konsulko.com>
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
d678a59d |
|
18-May-2024 |
Tom Rini <trini@konsulko.com> |
Revert "Merge patch series "arm: dts: am62-beagleplay: Fix Beagleplay Ethernet"" When bringing in the series 'arm: dts: am62-beagleplay: Fix Beagleplay Ethernet"' I failed to notice that b4 noticed it was based on next and so took that as the base commit and merged that part of next to master. This reverts commit c8ffd1356d42223cbb8c86280a083cc3c93e6426, reversing changes made to 2ee6f3a5f7550de3599faef9704e166e5dcace35. Reported-by: Jonas Karlman <jonas@kwiboo.se> Signed-off-by: Tom Rini <trini@konsulko.com>
|
#
7938ac65 |
|
01-May-2024 |
Tom Rini <trini@konsulko.com> |
mmc: Remove <common.h> and add needed includes Remove <common.h> from this driver directory and when needed add missing include files directly. Reviewed-by: Jaehoon Chung <jh80.chung@samsung.com> Reviewed-by: Peter Robinson <pbrobinson@gmail.com> Signed-off-by: Tom Rini <trini@konsulko.com>
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
d678a59d |
|
18-May-2024 |
Tom Rini <trini@konsulko.com> |
Revert "Merge patch series "arm: dts: am62-beagleplay: Fix Beagleplay Ethernet"" When bringing in the series 'arm: dts: am62-beagleplay: Fix Beagleplay Ethernet"' I failed to notice that b4 noticed it was based on next and so took that as the base commit and merged that part of next to master. This reverts commit c8ffd1356d42223cbb8c86280a083cc3c93e6426, reversing changes made to 2ee6f3a5f7550de3599faef9704e166e5dcace35. Reported-by: Jonas Karlman <jonas@kwiboo.se> Signed-off-by: Tom Rini <trini@konsulko.com>
|
#
7938ac65 |
|
01-May-2024 |
Tom Rini <trini@konsulko.com> |
mmc: Remove <common.h> and add needed includes Remove <common.h> from this driver directory and when needed add missing include files directly. Reviewed-by: Jaehoon Chung <jh80.chung@samsung.com> Reviewed-by: Peter Robinson <pbrobinson@gmail.com> Signed-off-by: Tom Rini <trini@konsulko.com>
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
d678a59d |
|
18-May-2024 |
Tom Rini <trini@konsulko.com> |
Revert "Merge patch series "arm: dts: am62-beagleplay: Fix Beagleplay Ethernet"" When bringing in the series 'arm: dts: am62-beagleplay: Fix Beagleplay Ethernet"' I failed to notice that b4 noticed it was based on next and so took that as the base commit and merged that part of next to master. This reverts commit c8ffd1356d42223cbb8c86280a083cc3c93e6426, reversing changes made to 2ee6f3a5f7550de3599faef9704e166e5dcace35. Reported-by: Jonas Karlman <jonas@kwiboo.se> Signed-off-by: Tom Rini <trini@konsulko.com>
|
#
7938ac65 |
|
01-May-2024 |
Tom Rini <trini@konsulko.com> |
mmc: Remove <common.h> and add needed includes Remove <common.h> from this driver directory and when needed add missing include files directly. Reviewed-by: Jaehoon Chung <jh80.chung@samsung.com> Reviewed-by: Peter Robinson <pbrobinson@gmail.com> Signed-off-by: Tom Rini <trini@konsulko.com>
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
d678a59d |
|
18-May-2024 |
Tom Rini <trini@konsulko.com> |
Revert "Merge patch series "arm: dts: am62-beagleplay: Fix Beagleplay Ethernet"" When bringing in the series 'arm: dts: am62-beagleplay: Fix Beagleplay Ethernet"' I failed to notice that b4 noticed it was based on next and so took that as the base commit and merged that part of next to master. This reverts commit c8ffd1356d42223cbb8c86280a083cc3c93e6426, reversing changes made to 2ee6f3a5f7550de3599faef9704e166e5dcace35. Reported-by: Jonas Karlman <jonas@kwiboo.se> Signed-off-by: Tom Rini <trini@konsulko.com>
|
#
7938ac65 |
|
01-May-2024 |
Tom Rini <trini@konsulko.com> |
mmc: Remove <common.h> and add needed includes Remove <common.h> from this driver directory and when needed add missing include files directly. Reviewed-by: Jaehoon Chung <jh80.chung@samsung.com> Reviewed-by: Peter Robinson <pbrobinson@gmail.com> Signed-off-by: Tom Rini <trini@konsulko.com>
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
d678a59d |
|
18-May-2024 |
Tom Rini <trini@konsulko.com> |
Revert "Merge patch series "arm: dts: am62-beagleplay: Fix Beagleplay Ethernet"" When bringing in the series 'arm: dts: am62-beagleplay: Fix Beagleplay Ethernet"' I failed to notice that b4 noticed it was based on next and so took that as the base commit and merged that part of next to master. This reverts commit c8ffd1356d42223cbb8c86280a083cc3c93e6426, reversing changes made to 2ee6f3a5f7550de3599faef9704e166e5dcace35. Reported-by: Jonas Karlman <jonas@kwiboo.se> Signed-off-by: Tom Rini <trini@konsulko.com>
|
#
7938ac65 |
|
01-May-2024 |
Tom Rini <trini@konsulko.com> |
mmc: Remove <common.h> and add needed includes Remove <common.h> from this driver directory and when needed add missing include files directly. Reviewed-by: Jaehoon Chung <jh80.chung@samsung.com> Reviewed-by: Peter Robinson <pbrobinson@gmail.com> Signed-off-by: Tom Rini <trini@konsulko.com>
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
d678a59d |
|
18-May-2024 |
Tom Rini <trini@konsulko.com> |
Revert "Merge patch series "arm: dts: am62-beagleplay: Fix Beagleplay Ethernet"" When bringing in the series 'arm: dts: am62-beagleplay: Fix Beagleplay Ethernet"' I failed to notice that b4 noticed it was based on next and so took that as the base commit and merged that part of next to master. This reverts commit c8ffd1356d42223cbb8c86280a083cc3c93e6426, reversing changes made to 2ee6f3a5f7550de3599faef9704e166e5dcace35. Reported-by: Jonas Karlman <jonas@kwiboo.se> Signed-off-by: Tom Rini <trini@konsulko.com>
|
#
7938ac65 |
|
01-May-2024 |
Tom Rini <trini@konsulko.com> |
mmc: Remove <common.h> and add needed includes Remove <common.h> from this driver directory and when needed add missing include files directly. Reviewed-by: Jaehoon Chung <jh80.chung@samsung.com> Reviewed-by: Peter Robinson <pbrobinson@gmail.com> Signed-off-by: Tom Rini <trini@konsulko.com>
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
d678a59d |
|
18-May-2024 |
Tom Rini <trini@konsulko.com> |
Revert "Merge patch series "arm: dts: am62-beagleplay: Fix Beagleplay Ethernet"" When bringing in the series 'arm: dts: am62-beagleplay: Fix Beagleplay Ethernet"' I failed to notice that b4 noticed it was based on next and so took that as the base commit and merged that part of next to master. This reverts commit c8ffd1356d42223cbb8c86280a083cc3c93e6426, reversing changes made to 2ee6f3a5f7550de3599faef9704e166e5dcace35. Reported-by: Jonas Karlman <jonas@kwiboo.se> Signed-off-by: Tom Rini <trini@konsulko.com>
|
#
7938ac65 |
|
01-May-2024 |
Tom Rini <trini@konsulko.com> |
mmc: Remove <common.h> and add needed includes Remove <common.h> from this driver directory and when needed add missing include files directly. Reviewed-by: Jaehoon Chung <jh80.chung@samsung.com> Reviewed-by: Peter Robinson <pbrobinson@gmail.com> Signed-off-by: Tom Rini <trini@konsulko.com>
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
d678a59d |
|
18-May-2024 |
Tom Rini <trini@konsulko.com> |
Revert "Merge patch series "arm: dts: am62-beagleplay: Fix Beagleplay Ethernet"" When bringing in the series 'arm: dts: am62-beagleplay: Fix Beagleplay Ethernet"' I failed to notice that b4 noticed it was based on next and so took that as the base commit and merged that part of next to master. This reverts commit c8ffd1356d42223cbb8c86280a083cc3c93e6426, reversing changes made to 2ee6f3a5f7550de3599faef9704e166e5dcace35. Reported-by: Jonas Karlman <jonas@kwiboo.se> Signed-off-by: Tom Rini <trini@konsulko.com>
|
#
7938ac65 |
|
01-May-2024 |
Tom Rini <trini@konsulko.com> |
mmc: Remove <common.h> and add needed includes Remove <common.h> from this driver directory and when needed add missing include files directly. Reviewed-by: Jaehoon Chung <jh80.chung@samsung.com> Reviewed-by: Peter Robinson <pbrobinson@gmail.com> Signed-off-by: Tom Rini <trini@konsulko.com>
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
d678a59d |
|
18-May-2024 |
Tom Rini <trini@konsulko.com> |
Revert "Merge patch series "arm: dts: am62-beagleplay: Fix Beagleplay Ethernet"" When bringing in the series 'arm: dts: am62-beagleplay: Fix Beagleplay Ethernet"' I failed to notice that b4 noticed it was based on next and so took that as the base commit and merged that part of next to master. This reverts commit c8ffd1356d42223cbb8c86280a083cc3c93e6426, reversing changes made to 2ee6f3a5f7550de3599faef9704e166e5dcace35. Reported-by: Jonas Karlman <jonas@kwiboo.se> Signed-off-by: Tom Rini <trini@konsulko.com>
|
#
7938ac65 |
|
01-May-2024 |
Tom Rini <trini@konsulko.com> |
mmc: Remove <common.h> and add needed includes Remove <common.h> from this driver directory and when needed add missing include files directly. Reviewed-by: Jaehoon Chung <jh80.chung@samsung.com> Reviewed-by: Peter Robinson <pbrobinson@gmail.com> Signed-off-by: Tom Rini <trini@konsulko.com>
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
d678a59d |
|
18-May-2024 |
Tom Rini <trini@konsulko.com> |
Revert "Merge patch series "arm: dts: am62-beagleplay: Fix Beagleplay Ethernet"" When bringing in the series 'arm: dts: am62-beagleplay: Fix Beagleplay Ethernet"' I failed to notice that b4 noticed it was based on next and so took that as the base commit and merged that part of next to master. This reverts commit c8ffd1356d42223cbb8c86280a083cc3c93e6426, reversing changes made to 2ee6f3a5f7550de3599faef9704e166e5dcace35. Reported-by: Jonas Karlman <jonas@kwiboo.se> Signed-off-by: Tom Rini <trini@konsulko.com>
|
#
7938ac65 |
|
01-May-2024 |
Tom Rini <trini@konsulko.com> |
mmc: Remove <common.h> and add needed includes Remove <common.h> from this driver directory and when needed add missing include files directly. Reviewed-by: Jaehoon Chung <jh80.chung@samsung.com> Reviewed-by: Peter Robinson <pbrobinson@gmail.com> Signed-off-by: Tom Rini <trini@konsulko.com>
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
d678a59d |
|
18-May-2024 |
Tom Rini <trini@konsulko.com> |
Revert "Merge patch series "arm: dts: am62-beagleplay: Fix Beagleplay Ethernet"" When bringing in the series 'arm: dts: am62-beagleplay: Fix Beagleplay Ethernet"' I failed to notice that b4 noticed it was based on next and so took that as the base commit and merged that part of next to master. This reverts commit c8ffd1356d42223cbb8c86280a083cc3c93e6426, reversing changes made to 2ee6f3a5f7550de3599faef9704e166e5dcace35. Reported-by: Jonas Karlman <jonas@kwiboo.se> Signed-off-by: Tom Rini <trini@konsulko.com>
|
#
7938ac65 |
|
01-May-2024 |
Tom Rini <trini@konsulko.com> |
mmc: Remove <common.h> and add needed includes Remove <common.h> from this driver directory and when needed add missing include files directly. Reviewed-by: Jaehoon Chung <jh80.chung@samsung.com> Reviewed-by: Peter Robinson <pbrobinson@gmail.com> Signed-off-by: Tom Rini <trini@konsulko.com>
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
d678a59d |
|
18-May-2024 |
Tom Rini <trini@konsulko.com> |
Revert "Merge patch series "arm: dts: am62-beagleplay: Fix Beagleplay Ethernet"" When bringing in the series 'arm: dts: am62-beagleplay: Fix Beagleplay Ethernet"' I failed to notice that b4 noticed it was based on next and so took that as the base commit and merged that part of next to master. This reverts commit c8ffd1356d42223cbb8c86280a083cc3c93e6426, reversing changes made to 2ee6f3a5f7550de3599faef9704e166e5dcace35. Reported-by: Jonas Karlman <jonas@kwiboo.se> Signed-off-by: Tom Rini <trini@konsulko.com>
|
#
7938ac65 |
|
01-May-2024 |
Tom Rini <trini@konsulko.com> |
mmc: Remove <common.h> and add needed includes Remove <common.h> from this driver directory and when needed add missing include files directly. Reviewed-by: Jaehoon Chung <jh80.chung@samsung.com> Reviewed-by: Peter Robinson <pbrobinson@gmail.com> Signed-off-by: Tom Rini <trini@konsulko.com>
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
d678a59d |
|
18-May-2024 |
Tom Rini <trini@konsulko.com> |
Revert "Merge patch series "arm: dts: am62-beagleplay: Fix Beagleplay Ethernet"" When bringing in the series 'arm: dts: am62-beagleplay: Fix Beagleplay Ethernet"' I failed to notice that b4 noticed it was based on next and so took that as the base commit and merged that part of next to master. This reverts commit c8ffd1356d42223cbb8c86280a083cc3c93e6426, reversing changes made to 2ee6f3a5f7550de3599faef9704e166e5dcace35. Reported-by: Jonas Karlman <jonas@kwiboo.se> Signed-off-by: Tom Rini <trini@konsulko.com>
|
#
7938ac65 |
|
01-May-2024 |
Tom Rini <trini@konsulko.com> |
mmc: Remove <common.h> and add needed includes Remove <common.h> from this driver directory and when needed add missing include files directly. Reviewed-by: Jaehoon Chung <jh80.chung@samsung.com> Reviewed-by: Peter Robinson <pbrobinson@gmail.com> Signed-off-by: Tom Rini <trini@konsulko.com>
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
d678a59d |
|
18-May-2024 |
Tom Rini <trini@konsulko.com> |
Revert "Merge patch series "arm: dts: am62-beagleplay: Fix Beagleplay Ethernet"" When bringing in the series 'arm: dts: am62-beagleplay: Fix Beagleplay Ethernet"' I failed to notice that b4 noticed it was based on next and so took that as the base commit and merged that part of next to master. This reverts commit c8ffd1356d42223cbb8c86280a083cc3c93e6426, reversing changes made to 2ee6f3a5f7550de3599faef9704e166e5dcace35. Reported-by: Jonas Karlman <jonas@kwiboo.se> Signed-off-by: Tom Rini <trini@konsulko.com>
|
#
7938ac65 |
|
01-May-2024 |
Tom Rini <trini@konsulko.com> |
mmc: Remove <common.h> and add needed includes Remove <common.h> from this driver directory and when needed add missing include files directly. Reviewed-by: Jaehoon Chung <jh80.chung@samsung.com> Reviewed-by: Peter Robinson <pbrobinson@gmail.com> Signed-off-by: Tom Rini <trini@konsulko.com>
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
d678a59d |
|
18-May-2024 |
Tom Rini <trini@konsulko.com> |
Revert "Merge patch series "arm: dts: am62-beagleplay: Fix Beagleplay Ethernet"" When bringing in the series 'arm: dts: am62-beagleplay: Fix Beagleplay Ethernet"' I failed to notice that b4 noticed it was based on next and so took that as the base commit and merged that part of next to master. This reverts commit c8ffd1356d42223cbb8c86280a083cc3c93e6426, reversing changes made to 2ee6f3a5f7550de3599faef9704e166e5dcace35. Reported-by: Jonas Karlman <jonas@kwiboo.se> Signed-off-by: Tom Rini <trini@konsulko.com>
|
#
7938ac65 |
|
01-May-2024 |
Tom Rini <trini@konsulko.com> |
mmc: Remove <common.h> and add needed includes Remove <common.h> from this driver directory and when needed add missing include files directly. Reviewed-by: Jaehoon Chung <jh80.chung@samsung.com> Reviewed-by: Peter Robinson <pbrobinson@gmail.com> Signed-off-by: Tom Rini <trini@konsulko.com>
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
d678a59d |
|
18-May-2024 |
Tom Rini <trini@konsulko.com> |
Revert "Merge patch series "arm: dts: am62-beagleplay: Fix Beagleplay Ethernet"" When bringing in the series 'arm: dts: am62-beagleplay: Fix Beagleplay Ethernet"' I failed to notice that b4 noticed it was based on next and so took that as the base commit and merged that part of next to master. This reverts commit c8ffd1356d42223cbb8c86280a083cc3c93e6426, reversing changes made to 2ee6f3a5f7550de3599faef9704e166e5dcace35. Reported-by: Jonas Karlman <jonas@kwiboo.se> Signed-off-by: Tom Rini <trini@konsulko.com>
|
#
7938ac65 |
|
01-May-2024 |
Tom Rini <trini@konsulko.com> |
mmc: Remove <common.h> and add needed includes Remove <common.h> from this driver directory and when needed add missing include files directly. Reviewed-by: Jaehoon Chung <jh80.chung@samsung.com> Reviewed-by: Peter Robinson <pbrobinson@gmail.com> Signed-off-by: Tom Rini <trini@konsulko.com>
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
d678a59d |
|
18-May-2024 |
Tom Rini <trini@konsulko.com> |
Revert "Merge patch series "arm: dts: am62-beagleplay: Fix Beagleplay Ethernet"" When bringing in the series 'arm: dts: am62-beagleplay: Fix Beagleplay Ethernet"' I failed to notice that b4 noticed it was based on next and so took that as the base commit and merged that part of next to master. This reverts commit c8ffd1356d42223cbb8c86280a083cc3c93e6426, reversing changes made to 2ee6f3a5f7550de3599faef9704e166e5dcace35. Reported-by: Jonas Karlman <jonas@kwiboo.se> Signed-off-by: Tom Rini <trini@konsulko.com>
|
#
7938ac65 |
|
01-May-2024 |
Tom Rini <trini@konsulko.com> |
mmc: Remove <common.h> and add needed includes Remove <common.h> from this driver directory and when needed add missing include files directly. Reviewed-by: Jaehoon Chung <jh80.chung@samsung.com> Reviewed-by: Peter Robinson <pbrobinson@gmail.com> Signed-off-by: Tom Rini <trini@konsulko.com>
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
7938ac65 |
|
01-May-2024 |
Tom Rini <trini@konsulko.com> |
mmc: Remove <common.h> and add needed includes Remove <common.h> from this driver directory and when needed add missing include files directly. Reviewed-by: Jaehoon Chung <jh80.chung@samsung.com> Reviewed-by: Peter Robinson <pbrobinson@gmail.com> Signed-off-by: Tom Rini <trini@konsulko.com>
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
7938ac65 |
|
01-May-2024 |
Tom Rini <trini@konsulko.com> |
mmc: Remove <common.h> and add needed includes Remove <common.h> from this driver directory and when needed add missing include files directly. Reviewed-by: Jaehoon Chung <jh80.chung@samsung.com> Reviewed-by: Peter Robinson <pbrobinson@gmail.com> Signed-off-by: Tom Rini <trini@konsulko.com>
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
7938ac65 |
|
01-May-2024 |
Tom Rini <trini@konsulko.com> |
mmc: Remove <common.h> and add needed includes Remove <common.h> from this driver directory and when needed add missing include files directly. Reviewed-by: Jaehoon Chung <jh80.chung@samsung.com> Reviewed-by: Peter Robinson <pbrobinson@gmail.com> Signed-off-by: Tom Rini <trini@konsulko.com>
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
7938ac65 |
|
01-May-2024 |
Tom Rini <trini@konsulko.com> |
mmc: Remove <common.h> and add needed includes Remove <common.h> from this driver directory and when needed add missing include files directly. Reviewed-by: Jaehoon Chung <jh80.chung@samsung.com> Reviewed-by: Peter Robinson <pbrobinson@gmail.com> Signed-off-by: Tom Rini <trini@konsulko.com>
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
c9309f40 |
|
16-Dec-2023 |
Sean Anderson <seanga2@gmail.com> |
treewide: Remove clk_free This function is a no-op. Remove it. Signed-off-by: Sean Anderson <seanga2@gmail.com> Link: https://lore.kernel.org/r/20231216193843.2463779-3-seanga2@gmail.com
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marex@denx.de> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
caa4daa2 |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename 'platdata' variables to just 'plat' We use 'priv' for private data but often use 'platdata' for platform data. We can't really use 'pdata' since that is ambiguous (it could mean private or platform data). Rename some of the latter variables to end with 'plat' for consistency. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
41575d8e |
|
03-Dec-2020 |
Simon Glass <sjg@chromium.org> |
dm: treewide: Rename auto_alloc_size members to be shorter This construct is quite long-winded. In earlier days it made some sense since auto-allocation was a strange concept. But with driver model now used pretty universally, we can shorten this to 'auto'. This reduces verbosity and makes it easier to read. Coincidentally it also ensures that every declaration is on one line, thus making dtoc's job easier. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
336d4615 |
|
03-Feb-2020 |
Simon Glass <sjg@chromium.org> |
dm: core: Create a new header file for 'compat' features At present dm/device.h includes the linux-compatible features. This requires including linux/compat.h which in turn includes a lot of headers. One of these is malloc.h which we thus end up including in every file in U-Boot. Apart from the inefficiency of this, it is problematic for sandbox which needs to use the system malloc() in some files. Move the compatibility features into a separate header file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
992bcf4f |
|
11-Jan-2019 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Make DMA transfer end bit configurable Different versions of the SDHI core use either bit 17 or bit 20 for the DTRAEND indication, which can differ even between SoC revisions. Make the DTRAEND bit position part of the driver private data, so that the probe function can set this accordingly. Set this to 20 on Socionext SoCs and either 17 or 20 on Renesas SoCs, depending on the SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8ec6a04b |
|
13-Jun-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Switch to clock framework Switch the driver to using clk_get_rate()/clk_set_rate() instead of caching the mclk frequency in it's private data. This is required on the SDHI variant of the controller, where the upstream mclk need to be adjusted when using UHS modes. Platforms which do not support clock framework or do not support it in eg. SPL default to 100 MHz clock. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> --- V2: - Fix build on certain platforms using SPL without clock framework V3: - Turn clk_get_rate into a callback and fill it as needed on both renesas and socionext platforms
|
#
c3ab1e11 |
|
09-Sep-2018 |
Masahiro Yamada <yamada.masahiro@socionext.com> |
mmc: uniphier-sd: sync with Linux Sync with the driver code and the binding recently merged in Linux. Signed-off-by: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
83d290c5 |
|
06-May-2018 |
Tom Rini <trini@konsulko.com> |
SPDX: Convert all of our single license tags to Linux Kernel style When U-Boot started using SPDX tags we were among the early adopters and there weren't a lot of other examples to borrow from. So we picked the area of the file that usually had a full license text and replaced it with an appropriate SPDX-License-Identifier: entry. Since then, the Linux Kernel has adopted SPDX tags and they place it as the very first line in a file (except where shebangs are used, then it's second line) and with slightly different comment styles than us. In part due to community overlap, in part due to better tag visibility and in part for other minor reasons, switch over to that style. This commit changes all instances where we have a single declared license in the tag as both the before and after are identical in tag contents. There's also a few places where I found we did not have a tag and have introduced one. Signed-off-by: Tom Rini <trini@konsulko.com>
|
#
fc2d0302 |
|
20-Apr-2018 |
Masahiro Yamada <yamada.masahiro@socionext.com> |
mmc: uniphier-sd: skip clock set-up for SPL The size of SPL is hitting the limit (64KB) for uniphier_v7_defconfig. When booting from SD/eMMC, obviously its clock has been properly set up by the boot ROM. Acutually, no need to re-initialize the clock in SPL. Using a clock driver would generalize the SoC specific code, but solving the memory footprint problem would win. Signed-off-by: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
30b5d9aa |
|
20-Apr-2018 |
Masahiro Yamada <yamada.masahiro@socionext.com> |
mmc: tmio: move clk_enable() to each driver's probe function I need to differentiate the clock handling for uniphier-sd. Move it to each driver's probe function from the tmio common code so that renesas-sdhi will not be affected. Signed-off-by: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
cb0b6b03 |
|
13-Apr-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: tmio: Rename Matsushita to TMIO Synchronize the naming with Linux, call the common code TMIO. No functional change. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Jaehoon Chung <jh80.chung@samsung.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
c769e609 |
|
08-Apr-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: uniphier: Allow passing quirks to the probe function Certain instances of the SD IP require more elaborate digging in the DT to figure out which variant of the SD IP is in use. Allow explicit passing of the quirks into the probe function. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Jaehoon Chung <jh80.chung@samsung.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
e94cad93 |
|
08-Apr-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: uniphier: Split out SoC specific bits from the driver Factor out common code from the uniphier SD driver, change the prefix of the functions from uniphier_sd_ to matsu_sd_ and create separate renesas-sdhi.c driver. Thus far, all the code is still compiled when CONFIG_UNIPHIER_MMC is selected and there is no functional change. This patch is a preparation for further split of the SoC specific parts of the Matsushita SD driver, used both on Uniphier and R-Car. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Jaehoon Chung <jh80.chung@samsung.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
d6eb25c2 |
|
26-Feb-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: uniphier-sd: Add R8A77965 M3N entries Add entries for the R8A77965 M3N SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Nobuhiro Iwamatsu <iwamatsu@nigauri.org> Cc: Jaehoon Chung <jh80.chung@samsung.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
0b75cc3f |
|
17-Jan-2018 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: uniphier-sd: Add compatible strings for RCar Gen2 Add DT compatible strings for RCar Gen2 SoCs, so that this driver can bind with them. Unlike Gen3, which uses 64bit FIFO, the Gen2 uses 16bit FIFO. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Jaehoon Chung <jh80.chung@samsung.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
af098530 |
|
21-Oct-2017 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: uniphier-sd: Add R8A77995 D3 compatible Add new compatible to the Uniphier SD driver for R8A77995 D3 SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> Cc: Nobuhiro Iwamatsu <iwamatsu@nigauri.org>
|
#
6ba2382f |
|
21-Oct-2017 |
Marek Vasut <marek.vasut+renesas@gmail.com> |
mmc: uniphier-sd: Add R8A77970 V3M compatible Add new compatible to the Uniphier SD driver for R8A77970 V3M SoC. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> Cc: Nobuhiro Iwamatsu <iwamatsu@nigauri.org>
|
#
9f13021f |
|
15-Sep-2017 |
Marek Vasut <marek.vasut@gmail.com> |
mmc: uniphier-sd: Add vqmmc regulator support Add initial support for setting the vqmmc regulator. Since we do not support 1V8 modes, set the regulator to 3V3 and enable it. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> Cc: Jaehoon Chung <jh80.chung@samsung.com> Acked-by: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
d6c40031 |
|
26-Sep-2017 |
Marek Vasut <marek.vasut@gmail.com> |
mmc: uniphier-sd: Update the file to match V3 patchset Old version of the uniphier-sd 64bit IO support patchset V1 was applied by the maintainer, update the uniphier-sd.c with the changes from the V3 of the patchset. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> Cc: Jaehoon Chung <jh80.chung@samsung.com> Acked-by: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
b24633df |
|
21-Jul-2017 |
Marek Vasut <marek.vasut@gmail.com> |
mmc: uniphier-sd: Add support for R8A7795 and R7A7796 Add OF match entries and quirks for Renesas RCar Gen3 controllers into the driver. The IP this driver handles is in fact Matsushita one and in used both in Socionext and Renesas chips. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> Cc: Jaehoon Chung <jh80.chung@samsung.com>
|
#
4b26d5e3 |
|
21-Jul-2017 |
Marek Vasut <marek.vasut@gmail.com> |
mmc: uniphier-sd: Add support for quirks Check if the OF match has any associated data and if so, use those data as the controller quirks, otherwise fallback to the old method of reading the controller version register to figure out the quirks. This allows us to supply controller quirks on controllers which ie. do not have version register. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> Cc: Jaehoon Chung <jh80.chung@samsung.com>
|
#
484d9db4 |
|
21-Jul-2017 |
Marek Vasut <marek.vasut@gmail.com> |
mmc: uniphier-sd: Add support for 64bit FIFO The Renesas RCar Gen3 contains the same controller, originally Matsushita. This patch adds support for handling of the 64bit FIFO on this controller. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> Cc: Jaehoon Chung <jh80.chung@samsung.com>
|
#
1c99f68e |
|
21-Jul-2017 |
Marek Vasut <marek.vasut@gmail.com> |
mmc: uniphier-sd: Add support for 64bit controller The Renesas RCar Gen3 contains the same controller, originally Matsushita, yet the register addresses are shifted by 1 to the left. The whole controller is also 64bit, including the data FIFOs and RSP registers. This patch adds support for handling the register IO by shifting the register offset by 1 in the IO accessor functions. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> Cc: Jaehoon Chung <jh80.chung@samsung.com>
|
#
3d7b1d1b |
|
21-Jul-2017 |
Marek Vasut <marek.vasut@gmail.com> |
mmc: uniphier-sd: Factor out register IO This patch prepares the driver to support controller(s) with registers at locations shifted by constant. Pull out the readl()/writel() from the driver into separate functions, where the adjustment of the register offset can be easily contained. Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> Cc: Jaehoon Chung <jh80.chung@samsung.com>
|
#
b27af399 |
|
25-Aug-2017 |
Masahiro Yamada <yamada.masahiro@socionext.com> |
dma: import linux/dma-direction.h to consolidate enum dma_data_direction Import include/linux/dma-direction.h from Linux 4.13-rc7 and delete duplicated definitions of enum dma_data_direction. Signed-off-by: Masahiro Yamada <yamada.masahiro@socionext.com> Reviewed-by: Andy Shevchenko <andriy.shevchenko@linux.intel.com>
|
#
ac5efc35 |
|
21-Jul-2017 |
Marek Vasut <marek.vasut@gmail.com> |
mmc: uniphier-sd: Fix long response processing The long response entry 0..3 LSByte comes from the next response register MSByte, not from the next response register LSByte. Fix this to make the driver report correct values in response 136 . Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com> Cc: Masahiro Yamada <yamada.masahiro@socionext.com> Cc: Jaehoon Chung <jh80.chung@samsung.com> Acked-by: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
a821c4af |
|
17-May-2017 |
Simon Glass <sjg@chromium.org> |
dm: Rename dev_addr..() functions These support the flat device tree. We want to use the dev_read_..() prefix for functions that support both flat tree and live tree. So rename the existing functions to avoid confusion. In the end we will have: 1. dev_read_addr...() - works on devices, supports flat/live tree 2. devfdt_get_addr...() - current functions, flat tree only 3. of_get_address() etc. - new functions, live tree only All drivers will be written to use 1. That function will in turn call either 2 or 3 depending on whether the flat or live tree is in use. Note this involves changing some dead code - the imx_lpi2c.c file. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
9d922450 |
|
17-May-2017 |
Simon Glass <sjg@chromium.org> |
dm: Use dm.h header when driver mode is used This header includes things that are needed to make driver build. Adjust existing users to include that always, even if other dm/ includes are present Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
e160f7d4 |
|
17-Jan-2017 |
Simon Glass <sjg@chromium.org> |
dm: core: Replace of_offset with accessor At present devices use a simple integer offset to record the device tree node associated with the device. In preparation for supporting a live device tree, which uses a node pointer instead, refactor existing code to access this field through an inline function. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
14f47234 |
|
13-Sep-2016 |
Masahiro Yamada <yamada.masahiro@socionext.com> |
mmc: uniphier-sd: migrate to CONFIG_BLK This is the state-of-the-art MMC driver implementation. Signed-off-by: Masahiro Yamada <yamada.masahiro@socionext.com> Reviewed-by: Simon Glass <sjg@chromium.org>
|
#
4a89a24e |
|
24-Aug-2016 |
Masahiro Yamada <yamada.masahiro@socionext.com> |
mmc: uniphier-sd: just return if already set to desired clock rate With this, we can save unnecessary udelay(). Signed-off-by: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
8be12e28 |
|
24-Aug-2016 |
Masahiro Yamada <yamada.masahiro@socionext.com> |
mmc: uniphier-sd: return error code if unsupported width is given With the CONFIG_DM_MMC_OPS migration, the .set_ios callback can return an integer now. Return an appropriate error value rather than sudden death by BUG(). Signed-off-by: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
4eb00846 |
|
24-Aug-2016 |
Masahiro Yamada <yamada.masahiro@socionext.com> |
mmc: uniphier-sd: move uniphier_sd_init() below No more reason to define this function above the ops structure. Move it near the caller. Also, change its return type to void because it never fails. Signed-off-by: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
3937404f |
|
24-Aug-2016 |
Masahiro Yamada <yamada.masahiro@socionext.com> |
mmc: uniphier-sd: migrate to CONFIG_DM_MMC_OPS Catch up with the DM migration. As struct dm_mmc_ops does not have .init callback, call the init function directly from the probe function. Signed-off-by: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
4a70d262 |
|
12-Aug-2016 |
Masahiro Yamada <yamada.masahiro@socionext.com> |
mmc: uniphier-sd: add static qualifiers to probe and remove callbacks They are both only referenced in this file. Signed-off-by: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
915ffa52 |
|
19-Jul-2016 |
Jaehoon Chung <jh80.chung@samsung.com> |
mmc: use the generic error number Use the generic error number instead of specific error number. If use the generic error number, it can debug more easier. Signed-off-by: Jaehoon Chung <jh80.chung@samsung.com> Reviewed-by: Simon Glass <sjg@chromium.org> Reviewed-by: Minkyu Kang <mk7.kang@samsung.com>
|
#
4e3d8406 |
|
19-Jul-2016 |
Masahiro Yamada <yamada.masahiro@socionext.com> |
ARM: uniphier: use (devm_)ioremap() instead of map_sysmem() This does not have much impact on behavior, but makes code look more more like Linux. The use of devm_ioremap() often helps to delete .remove callbacks entirely. Signed-off-by: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
135aa950 |
|
17-Jun-2016 |
Stephen Warren <swarren@nvidia.com> |
clk: convert API to match reset/mailbox style The following changes are made to the clock API: * The concept of "clocks" and "peripheral clocks" are unified; each clock provider now implements a single set of clocks. This provides a simpler conceptual interface to clients, and better aligns with device tree clock bindings. * Clocks are now identified with a single "struct clk", rather than requiring clients to store the clock provider device and clock identity values separately. For simple clock consumers, this isolates clients from internal details of the clock API. * clk.h is split so it only contains the client/consumer API, whereas clk-uclass.h contains the provider API. This aligns with the recently added reset and mailbox APIs. * clk_ops .of_xlate(), .request(), and .free() are added so providers can customize these operations if needed. This also aligns with the recently added reset and mailbox APIs. * clk_disable() is added. * All users of the current clock APIs are updated. * Sandbox clock tests are updated to exercise clock lookup via DT, and clock enable/disable. * rkclk_get_clk() is removed and replaced with standard APIs. Buildman shows no clock-related errors for any board for which buildman can download a toolchain. test/py passes for sandbox (which invokes the dm clk test amongst others). Signed-off-by: Stephen Warren <swarren@nvidia.com> Acked-by: Simon Glass <sjg@chromium.org>
|
#
cffe5d86 |
|
01-May-2016 |
Simon Glass <sjg@chromium.org> |
dm: mmc: Set up the device pointer when using the MMC uclass Update the existing drivers to set up this new pointer. This will be required by the MMC uclass. Signed-off-by: Simon Glass <sjg@chromium.org>
|
#
4f80501b |
|
24-Mar-2016 |
Masahiro Yamada <yamada.masahiro@socionext.com> |
mmc: uniphier: use devm_get_addr() to get base address Currently, fdtdec_get_addr_size() does not support the address translation, so it cannot handle device trees with non-straight "ranges" properties. (This would be a problem with DTS for UniPhier ARMv8 SoCs.) Signed-off-by: Masahiro Yamada <yamada.masahiro@socionext.com>
|
#
a111bfbf |
|
18-Feb-2016 |
Masahiro Yamada <yamada.masahiro@socionext.com> |
mmc: uniphier: add driver for UniPhier SD/MMC host controller Add a driver for the on-chip SD/eMMC host controller used by UniPhier SoC family. Signed-off-by: Masahiro Yamada <yamada.masahiro@socionext.com>
|