1.13 |
|
10-Jun-2024 |
palle |
sun4v: add incomplete implementation of the CD-specific READ_DISCINFO and READ_TRACKINFO - probably needs some more work though...
|
#
1.12 |
|
09-Jun-2024 |
palle |
sun4v: fix vdsk so an iso image exported by the ldom virtual disk service is correctly detected as a cd device + some whitespace fixes
|
#
1.11 |
|
12-Dec-2023 |
andvar |
extract capacity variable to make VDSK_DEBUG enabled code build.
|
Revision tags: netbsd-10-0-RELEASE netbsd-10-0-RC6 netbsd-10-0-RC5 netbsd-10-0-RC4 netbsd-10-0-RC3 netbsd-10-0-RC2 thorpej-ifq-base thorpej-altq-separation-base netbsd-10-0-RC1 netbsd-10-base bouyer-sunxi-drm-base
|
#
1.10 |
|
16-May-2022 |
palle |
sun4v/vdsk: add handling of SCSI_REPORT_LUNS
|
#
1.9 |
|
04-Dec-2021 |
andvar |
fix typos in comments and log messages, mainly in establish(ed).
|
Revision tags: thorpej-i2c-spi-conf2-base
|
#
1.8 |
|
07-Aug-2021 |
thorpej |
Merge thorpej-cfargs2.
|
Revision tags: thorpej-futex2-base thorpej-cfargs2-base thorpej-i2c-spi-conf-base
|
#
1.7 |
|
25-Jun-2021 |
palle |
branches: 1.7.2; sun4v: vdsk - restart the ldc state machine when the ldc endpoint resets the link or a DATA/NACK/DRING_DATA message is received. These changes make the driver more robust. In a ldom with Solaris 11.4 SRU30 as primary domain (T5 host system) frequent resets and NACK messages are observed.
|
Revision tags: cjep_sun2x-base1 cjep_sun2x-base cjep_staticlib_x-base1 cjep_staticlib_x-base
|
#
1.6 |
|
24-Apr-2021 |
thorpej |
branches: 1.6.2; Merge thorpej-cfargs branch:
Simplify and make extensible the config_search() / config_found() / config_attach() interfaces: rather than having different variants for which arguments you want pass along, just have a single call that takes a variadic list of tag-value arguments.
Adjust all call sites: - Simplify wherever possible; don't pass along arguments that aren't actually needed. - Don't be explicit about what interface attribute is attaching if the device only has one. (More simplification.) - Add a config_probe() function to be used in indirect configuiration situations, making is visibly easier to see when indirect config is in play, and allowing for future change in semantics. (As of now, this is just a wrapper around config_match(), but that is an implementation detail.)
Remove unnecessary or redundant interface attributes where they're not needed.
There are currently 5 "cfargs" defined: - CFARG_SUBMATCH (submatch function for direct config) - CFARG_SEARCH (search function for indirect config) - CFARG_IATTR (interface attribte) - CFARG_LOCATORS (locators array) - CFARG_DEVHANDLE (devhandle_t - wraps OFW, ACPI, etc. handles)
...and a sentinel value CFARG_EOL.
Add some extra sanity checking to ensure that interface attributes aren't ambiguous.
Use CFARG_DEVHANDLE in MI FDT, OFW, and ACPI code, and macppc and shark ports to associate those device handles with device_t instance. This will trickle trough to more places over time (need back-end for pre-OFW Sun OBP; any others?).
|
Revision tags: thorpej-cfargs-base thorpej-futex-base bouyer-xenpvh-base2 phil-wifi-20200421 bouyer-xenpvh-base1 phil-wifi-20200411 bouyer-xenpvh-base is-mlppp-base phil-wifi-20200406 ad-namecache-base3 ad-namecache-base2 ad-namecache-base1 ad-namecache-base
|
#
1.5 |
|
19-Nov-2019 |
palle |
branches: 1.5.10; sun4v: added support for handling of opcode SCSI_MAINTENANCE_IN when using ldom based virtual disk
|
Revision tags: phil-wifi-20191119
|
#
1.4 |
|
01-Oct-2019 |
chs |
in many device attach paths, allocate memory with KM_SLEEP instead of KM_NOSLEEP and remove code to handle failures that can no longer happen.
|
Revision tags: netbsd-8-3-RELEASE netbsd-9-4-RELEASE netbsd-9-3-RELEASE netbsd-9-2-RELEASE netbsd-9-1-RELEASE netbsd-8-2-RELEASE netbsd-9-0-RELEASE netbsd-9-0-RC2 netbsd-9-0-RC1 netbsd-9-base phil-wifi-20190609 netbsd-8-1-RELEASE netbsd-8-1-RC1 isaki-audio2-base pgoyette-compat-merge-20190127 pgoyette-compat-20190127 pgoyette-compat-20190118 pgoyette-compat-1226 pgoyette-compat-1126 pgoyette-compat-1020 pgoyette-compat-0930 pgoyette-compat-0906 pgoyette-compat-0728 netbsd-8-0-RELEASE phil-wifi-base pgoyette-compat-0625 netbsd-8-0-RC2 pgoyette-compat-0521 pgoyette-compat-0502 pgoyette-compat-0422 netbsd-8-0-RC1 pgoyette-compat-0415 pgoyette-compat-0407 pgoyette-compat-0330 pgoyette-compat-0322 pgoyette-compat-0315 pgoyette-compat-base tls-maxphys-base-20171202 matt-nb8-mediatek-base nick-nhusb-base-20170825 perseant-stdc-iso10646-base netbsd-8-base prg-localcount2-base3 prg-localcount2-base2 prg-localcount2-base1 prg-localcount2-base pgoyette-localcount-20170426 bouyer-socketcan-base1 jdolecek-ncq-base pgoyette-localcount-20170320
|
#
1.3 |
|
03-Mar-2017 |
palle |
branches: 1.3.12; 1.3.16; sun4v: Fixed PR 51554 - Avoid unsafe allocation in ldc/vdsk
|
Revision tags: nick-nhusb-base-20170204 bouyer-socketcan-base pgoyette-localcount-20170107 nick-nhusb-base-20161204 pgoyette-localcount-20161104 nick-nhusb-base-20161004 localcount-20160914
|
#
1.2 |
|
20-Aug-2016 |
nakayama |
branches: 1.2.2; 1.2.4; 1.2.6; Avoid "cast to pointer from integer of different size" warning on 32-bit kernels.
|
#
1.1 |
|
19-Aug-2016 |
palle |
sun4v: vdsk and ldc drivers - from OpenBSD, but heavily adapted to NetBSD scsipi - access to a virtual disk served from a ldom primary domain now works
|
#
1.11 |
|
12-Dec-2023 |
andvar |
extract capacity variable to make VDSK_DEBUG enabled code build.
|
Revision tags: thorpej-ifq-base thorpej-altq-separation-base netbsd-10-0-RC1 netbsd-10-base bouyer-sunxi-drm-base
|
#
1.10 |
|
16-May-2022 |
palle |
sun4v/vdsk: add handling of SCSI_REPORT_LUNS
|
#
1.9 |
|
04-Dec-2021 |
andvar |
fix typos in comments and log messages, mainly in establish(ed).
|
Revision tags: thorpej-i2c-spi-conf2-base
|
#
1.8 |
|
07-Aug-2021 |
thorpej |
Merge thorpej-cfargs2.
|
Revision tags: thorpej-futex2-base thorpej-cfargs2-base thorpej-i2c-spi-conf-base
|
#
1.7 |
|
25-Jun-2021 |
palle |
branches: 1.7.2; sun4v: vdsk - restart the ldc state machine when the ldc endpoint resets the link or a DATA/NACK/DRING_DATA message is received. These changes make the driver more robust. In a ldom with Solaris 11.4 SRU30 as primary domain (T5 host system) frequent resets and NACK messages are observed.
|
Revision tags: cjep_sun2x-base1 cjep_sun2x-base cjep_staticlib_x-base1 cjep_staticlib_x-base
|
#
1.6 |
|
24-Apr-2021 |
thorpej |
branches: 1.6.2; Merge thorpej-cfargs branch:
Simplify and make extensible the config_search() / config_found() / config_attach() interfaces: rather than having different variants for which arguments you want pass along, just have a single call that takes a variadic list of tag-value arguments.
Adjust all call sites: - Simplify wherever possible; don't pass along arguments that aren't actually needed. - Don't be explicit about what interface attribute is attaching if the device only has one. (More simplification.) - Add a config_probe() function to be used in indirect configuiration situations, making is visibly easier to see when indirect config is in play, and allowing for future change in semantics. (As of now, this is just a wrapper around config_match(), but that is an implementation detail.)
Remove unnecessary or redundant interface attributes where they're not needed.
There are currently 5 "cfargs" defined: - CFARG_SUBMATCH (submatch function for direct config) - CFARG_SEARCH (search function for indirect config) - CFARG_IATTR (interface attribte) - CFARG_LOCATORS (locators array) - CFARG_DEVHANDLE (devhandle_t - wraps OFW, ACPI, etc. handles)
...and a sentinel value CFARG_EOL.
Add some extra sanity checking to ensure that interface attributes aren't ambiguous.
Use CFARG_DEVHANDLE in MI FDT, OFW, and ACPI code, and macppc and shark ports to associate those device handles with device_t instance. This will trickle trough to more places over time (need back-end for pre-OFW Sun OBP; any others?).
|
Revision tags: thorpej-cfargs-base thorpej-futex-base bouyer-xenpvh-base2 phil-wifi-20200421 bouyer-xenpvh-base1 phil-wifi-20200411 bouyer-xenpvh-base is-mlppp-base phil-wifi-20200406 ad-namecache-base3 ad-namecache-base2 ad-namecache-base1 ad-namecache-base
|
#
1.5 |
|
19-Nov-2019 |
palle |
branches: 1.5.10; sun4v: added support for handling of opcode SCSI_MAINTENANCE_IN when using ldom based virtual disk
|
Revision tags: phil-wifi-20191119
|
#
1.4 |
|
01-Oct-2019 |
chs |
in many device attach paths, allocate memory with KM_SLEEP instead of KM_NOSLEEP and remove code to handle failures that can no longer happen.
|
Revision tags: netbsd-9-3-RELEASE netbsd-9-2-RELEASE netbsd-9-1-RELEASE netbsd-8-2-RELEASE netbsd-9-0-RELEASE netbsd-9-0-RC2 netbsd-9-0-RC1 netbsd-9-base phil-wifi-20190609 netbsd-8-1-RELEASE netbsd-8-1-RC1 isaki-audio2-base pgoyette-compat-merge-20190127 pgoyette-compat-20190127 pgoyette-compat-20190118 pgoyette-compat-1226 pgoyette-compat-1126 pgoyette-compat-1020 pgoyette-compat-0930 pgoyette-compat-0906 pgoyette-compat-0728 netbsd-8-0-RELEASE phil-wifi-base pgoyette-compat-0625 netbsd-8-0-RC2 pgoyette-compat-0521 pgoyette-compat-0502 pgoyette-compat-0422 netbsd-8-0-RC1 pgoyette-compat-0415 pgoyette-compat-0407 pgoyette-compat-0330 pgoyette-compat-0322 pgoyette-compat-0315 pgoyette-compat-base tls-maxphys-base-20171202 matt-nb8-mediatek-base nick-nhusb-base-20170825 perseant-stdc-iso10646-base netbsd-8-base prg-localcount2-base3 prg-localcount2-base2 prg-localcount2-base1 prg-localcount2-base pgoyette-localcount-20170426 bouyer-socketcan-base1 jdolecek-ncq-base pgoyette-localcount-20170320
|
#
1.3 |
|
03-Mar-2017 |
palle |
branches: 1.3.12; 1.3.16; sun4v: Fixed PR 51554 - Avoid unsafe allocation in ldc/vdsk
|
Revision tags: nick-nhusb-base-20170204 bouyer-socketcan-base pgoyette-localcount-20170107 nick-nhusb-base-20161204 pgoyette-localcount-20161104 nick-nhusb-base-20161004 localcount-20160914
|
#
1.2 |
|
20-Aug-2016 |
nakayama |
branches: 1.2.2; 1.2.4; 1.2.6; Avoid "cast to pointer from integer of different size" warning on 32-bit kernels.
|
#
1.1 |
|
19-Aug-2016 |
palle |
sun4v: vdsk and ldc drivers - from OpenBSD, but heavily adapted to NetBSD scsipi - access to a virtual disk served from a ldom primary domain now works
|
#
1.10 |
|
16-May-2022 |
palle |
sun4v/vdsk: add handling of SCSI_REPORT_LUNS
|
#
1.9 |
|
04-Dec-2021 |
andvar |
fix typos in comments and log messages, mainly in establish(ed).
|
Revision tags: thorpej-i2c-spi-conf2-base
|
#
1.8 |
|
07-Aug-2021 |
thorpej |
Merge thorpej-cfargs2.
|
Revision tags: thorpej-futex2-base thorpej-cfargs2-base thorpej-i2c-spi-conf-base
|
#
1.7 |
|
25-Jun-2021 |
palle |
branches: 1.7.2; sun4v: vdsk - restart the ldc state machine when the ldc endpoint resets the link or a DATA/NACK/DRING_DATA message is received. These changes make the driver more robust. In a ldom with Solaris 11.4 SRU30 as primary domain (T5 host system) frequent resets and NACK messages are observed.
|
Revision tags: cjep_sun2x-base1 cjep_sun2x-base cjep_staticlib_x-base1 cjep_staticlib_x-base
|
#
1.6 |
|
24-Apr-2021 |
thorpej |
branches: 1.6.2; Merge thorpej-cfargs branch:
Simplify and make extensible the config_search() / config_found() / config_attach() interfaces: rather than having different variants for which arguments you want pass along, just have a single call that takes a variadic list of tag-value arguments.
Adjust all call sites: - Simplify wherever possible; don't pass along arguments that aren't actually needed. - Don't be explicit about what interface attribute is attaching if the device only has one. (More simplification.) - Add a config_probe() function to be used in indirect configuiration situations, making is visibly easier to see when indirect config is in play, and allowing for future change in semantics. (As of now, this is just a wrapper around config_match(), but that is an implementation detail.)
Remove unnecessary or redundant interface attributes where they're not needed.
There are currently 5 "cfargs" defined: - CFARG_SUBMATCH (submatch function for direct config) - CFARG_SEARCH (search function for indirect config) - CFARG_IATTR (interface attribte) - CFARG_LOCATORS (locators array) - CFARG_DEVHANDLE (devhandle_t - wraps OFW, ACPI, etc. handles)
...and a sentinel value CFARG_EOL.
Add some extra sanity checking to ensure that interface attributes aren't ambiguous.
Use CFARG_DEVHANDLE in MI FDT, OFW, and ACPI code, and macppc and shark ports to associate those device handles with device_t instance. This will trickle trough to more places over time (need back-end for pre-OFW Sun OBP; any others?).
|
Revision tags: thorpej-cfargs-base thorpej-futex-base bouyer-xenpvh-base2 phil-wifi-20200421 bouyer-xenpvh-base1 phil-wifi-20200411 bouyer-xenpvh-base is-mlppp-base phil-wifi-20200406 ad-namecache-base3 ad-namecache-base2 ad-namecache-base1 ad-namecache-base
|
#
1.5 |
|
19-Nov-2019 |
palle |
branches: 1.5.10; sun4v: added support for handling of opcode SCSI_MAINTENANCE_IN when using ldom based virtual disk
|
Revision tags: phil-wifi-20191119
|
#
1.4 |
|
01-Oct-2019 |
chs |
in many device attach paths, allocate memory with KM_SLEEP instead of KM_NOSLEEP and remove code to handle failures that can no longer happen.
|
Revision tags: netbsd-9-2-RELEASE netbsd-9-1-RELEASE netbsd-8-2-RELEASE netbsd-9-0-RELEASE netbsd-9-0-RC2 netbsd-9-0-RC1 netbsd-9-base phil-wifi-20190609 netbsd-8-1-RELEASE netbsd-8-1-RC1 isaki-audio2-base pgoyette-compat-merge-20190127 pgoyette-compat-20190127 pgoyette-compat-20190118 pgoyette-compat-1226 pgoyette-compat-1126 pgoyette-compat-1020 pgoyette-compat-0930 pgoyette-compat-0906 pgoyette-compat-0728 netbsd-8-0-RELEASE phil-wifi-base pgoyette-compat-0625 netbsd-8-0-RC2 pgoyette-compat-0521 pgoyette-compat-0502 pgoyette-compat-0422 netbsd-8-0-RC1 pgoyette-compat-0415 pgoyette-compat-0407 pgoyette-compat-0330 pgoyette-compat-0322 pgoyette-compat-0315 pgoyette-compat-base tls-maxphys-base-20171202 matt-nb8-mediatek-base nick-nhusb-base-20170825 perseant-stdc-iso10646-base netbsd-8-base prg-localcount2-base3 prg-localcount2-base2 prg-localcount2-base1 prg-localcount2-base pgoyette-localcount-20170426 bouyer-socketcan-base1 jdolecek-ncq-base pgoyette-localcount-20170320
|
#
1.3 |
|
03-Mar-2017 |
palle |
branches: 1.3.12; 1.3.16; sun4v: Fixed PR 51554 - Avoid unsafe allocation in ldc/vdsk
|
Revision tags: nick-nhusb-base-20170204 bouyer-socketcan-base pgoyette-localcount-20170107 nick-nhusb-base-20161204 pgoyette-localcount-20161104 nick-nhusb-base-20161004 localcount-20160914
|
#
1.2 |
|
20-Aug-2016 |
nakayama |
branches: 1.2.2; 1.2.4; 1.2.6; Avoid "cast to pointer from integer of different size" warning on 32-bit kernels.
|
#
1.1 |
|
19-Aug-2016 |
palle |
sun4v: vdsk and ldc drivers - from OpenBSD, but heavily adapted to NetBSD scsipi - access to a virtual disk served from a ldom primary domain now works
|
#
1.9 |
|
04-Dec-2021 |
andvar |
fix typos in comments and log messages, mainly in establish(ed).
|
Revision tags: thorpej-i2c-spi-conf2-base
|
#
1.8 |
|
07-Aug-2021 |
thorpej |
Merge thorpej-cfargs2.
|
Revision tags: thorpej-futex2-base thorpej-cfargs2-base thorpej-i2c-spi-conf-base
|
#
1.7 |
|
25-Jun-2021 |
palle |
branches: 1.7.2; sun4v: vdsk - restart the ldc state machine when the ldc endpoint resets the link or a DATA/NACK/DRING_DATA message is received. These changes make the driver more robust. In a ldom with Solaris 11.4 SRU30 as primary domain (T5 host system) frequent resets and NACK messages are observed.
|
Revision tags: cjep_sun2x-base1 cjep_sun2x-base cjep_staticlib_x-base1 cjep_staticlib_x-base
|
#
1.6 |
|
24-Apr-2021 |
thorpej |
branches: 1.6.2; Merge thorpej-cfargs branch:
Simplify and make extensible the config_search() / config_found() / config_attach() interfaces: rather than having different variants for which arguments you want pass along, just have a single call that takes a variadic list of tag-value arguments.
Adjust all call sites: - Simplify wherever possible; don't pass along arguments that aren't actually needed. - Don't be explicit about what interface attribute is attaching if the device only has one. (More simplification.) - Add a config_probe() function to be used in indirect configuiration situations, making is visibly easier to see when indirect config is in play, and allowing for future change in semantics. (As of now, this is just a wrapper around config_match(), but that is an implementation detail.)
Remove unnecessary or redundant interface attributes where they're not needed.
There are currently 5 "cfargs" defined: - CFARG_SUBMATCH (submatch function for direct config) - CFARG_SEARCH (search function for indirect config) - CFARG_IATTR (interface attribte) - CFARG_LOCATORS (locators array) - CFARG_DEVHANDLE (devhandle_t - wraps OFW, ACPI, etc. handles)
...and a sentinel value CFARG_EOL.
Add some extra sanity checking to ensure that interface attributes aren't ambiguous.
Use CFARG_DEVHANDLE in MI FDT, OFW, and ACPI code, and macppc and shark ports to associate those device handles with device_t instance. This will trickle trough to more places over time (need back-end for pre-OFW Sun OBP; any others?).
|
Revision tags: thorpej-cfargs-base thorpej-futex-base bouyer-xenpvh-base2 phil-wifi-20200421 bouyer-xenpvh-base1 phil-wifi-20200411 bouyer-xenpvh-base is-mlppp-base phil-wifi-20200406 ad-namecache-base3 ad-namecache-base2 ad-namecache-base1 ad-namecache-base
|
#
1.5 |
|
19-Nov-2019 |
palle |
branches: 1.5.10; sun4v: added support for handling of opcode SCSI_MAINTENANCE_IN when using ldom based virtual disk
|
Revision tags: phil-wifi-20191119
|
#
1.4 |
|
01-Oct-2019 |
chs |
in many device attach paths, allocate memory with KM_SLEEP instead of KM_NOSLEEP and remove code to handle failures that can no longer happen.
|
Revision tags: netbsd-9-2-RELEASE netbsd-9-1-RELEASE netbsd-8-2-RELEASE netbsd-9-0-RELEASE netbsd-9-0-RC2 netbsd-9-0-RC1 netbsd-9-base phil-wifi-20190609 netbsd-8-1-RELEASE netbsd-8-1-RC1 isaki-audio2-base pgoyette-compat-merge-20190127 pgoyette-compat-20190127 pgoyette-compat-20190118 pgoyette-compat-1226 pgoyette-compat-1126 pgoyette-compat-1020 pgoyette-compat-0930 pgoyette-compat-0906 pgoyette-compat-0728 netbsd-8-0-RELEASE phil-wifi-base pgoyette-compat-0625 netbsd-8-0-RC2 pgoyette-compat-0521 pgoyette-compat-0502 pgoyette-compat-0422 netbsd-8-0-RC1 pgoyette-compat-0415 pgoyette-compat-0407 pgoyette-compat-0330 pgoyette-compat-0322 pgoyette-compat-0315 pgoyette-compat-base tls-maxphys-base-20171202 matt-nb8-mediatek-base nick-nhusb-base-20170825 perseant-stdc-iso10646-base netbsd-8-base prg-localcount2-base3 prg-localcount2-base2 prg-localcount2-base1 prg-localcount2-base pgoyette-localcount-20170426 bouyer-socketcan-base1 jdolecek-ncq-base pgoyette-localcount-20170320
|
#
1.3 |
|
03-Mar-2017 |
palle |
branches: 1.3.12; 1.3.16; sun4v: Fixed PR 51554 - Avoid unsafe allocation in ldc/vdsk
|
Revision tags: nick-nhusb-base-20170204 bouyer-socketcan-base pgoyette-localcount-20170107 nick-nhusb-base-20161204 pgoyette-localcount-20161104 nick-nhusb-base-20161004 localcount-20160914
|
#
1.2 |
|
20-Aug-2016 |
nakayama |
branches: 1.2.2; 1.2.4; 1.2.6; Avoid "cast to pointer from integer of different size" warning on 32-bit kernels.
|
#
1.1 |
|
19-Aug-2016 |
palle |
sun4v: vdsk and ldc drivers - from OpenBSD, but heavily adapted to NetBSD scsipi - access to a virtual disk served from a ldom primary domain now works
|
#
1.8 |
|
07-Aug-2021 |
thorpej |
Merge thorpej-cfargs2.
|
Revision tags: thorpej-futex2-base thorpej-cfargs2-base thorpej-i2c-spi-conf-base
|
#
1.7 |
|
25-Jun-2021 |
palle |
branches: 1.7.2; sun4v: vdsk - restart the ldc state machine when the ldc endpoint resets the link or a DATA/NACK/DRING_DATA message is received. These changes make the driver more robust. In a ldom with Solaris 11.4 SRU30 as primary domain (T5 host system) frequent resets and NACK messages are observed.
|
Revision tags: cjep_sun2x-base1 cjep_sun2x-base cjep_staticlib_x-base1 cjep_staticlib_x-base
|
#
1.6 |
|
24-Apr-2021 |
thorpej |
branches: 1.6.2; Merge thorpej-cfargs branch:
Simplify and make extensible the config_search() / config_found() / config_attach() interfaces: rather than having different variants for which arguments you want pass along, just have a single call that takes a variadic list of tag-value arguments.
Adjust all call sites: - Simplify wherever possible; don't pass along arguments that aren't actually needed. - Don't be explicit about what interface attribute is attaching if the device only has one. (More simplification.) - Add a config_probe() function to be used in indirect configuiration situations, making is visibly easier to see when indirect config is in play, and allowing for future change in semantics. (As of now, this is just a wrapper around config_match(), but that is an implementation detail.)
Remove unnecessary or redundant interface attributes where they're not needed.
There are currently 5 "cfargs" defined: - CFARG_SUBMATCH (submatch function for direct config) - CFARG_SEARCH (search function for indirect config) - CFARG_IATTR (interface attribte) - CFARG_LOCATORS (locators array) - CFARG_DEVHANDLE (devhandle_t - wraps OFW, ACPI, etc. handles)
...and a sentinel value CFARG_EOL.
Add some extra sanity checking to ensure that interface attributes aren't ambiguous.
Use CFARG_DEVHANDLE in MI FDT, OFW, and ACPI code, and macppc and shark ports to associate those device handles with device_t instance. This will trickle trough to more places over time (need back-end for pre-OFW Sun OBP; any others?).
|
Revision tags: thorpej-cfargs-base thorpej-futex-base bouyer-xenpvh-base2 phil-wifi-20200421 bouyer-xenpvh-base1 phil-wifi-20200411 bouyer-xenpvh-base is-mlppp-base phil-wifi-20200406 ad-namecache-base3 ad-namecache-base2 ad-namecache-base1 ad-namecache-base
|
#
1.5 |
|
19-Nov-2019 |
palle |
branches: 1.5.10; sun4v: added support for handling of opcode SCSI_MAINTENANCE_IN when using ldom based virtual disk
|
Revision tags: phil-wifi-20191119
|
#
1.4 |
|
01-Oct-2019 |
chs |
in many device attach paths, allocate memory with KM_SLEEP instead of KM_NOSLEEP and remove code to handle failures that can no longer happen.
|
Revision tags: netbsd-9-2-RELEASE netbsd-9-1-RELEASE netbsd-8-2-RELEASE netbsd-9-0-RELEASE netbsd-9-0-RC2 netbsd-9-0-RC1 netbsd-9-base phil-wifi-20190609 netbsd-8-1-RELEASE netbsd-8-1-RC1 isaki-audio2-base pgoyette-compat-merge-20190127 pgoyette-compat-20190127 pgoyette-compat-20190118 pgoyette-compat-1226 pgoyette-compat-1126 pgoyette-compat-1020 pgoyette-compat-0930 pgoyette-compat-0906 pgoyette-compat-0728 netbsd-8-0-RELEASE phil-wifi-base pgoyette-compat-0625 netbsd-8-0-RC2 pgoyette-compat-0521 pgoyette-compat-0502 pgoyette-compat-0422 netbsd-8-0-RC1 pgoyette-compat-0415 pgoyette-compat-0407 pgoyette-compat-0330 pgoyette-compat-0322 pgoyette-compat-0315 pgoyette-compat-base tls-maxphys-base-20171202 matt-nb8-mediatek-base nick-nhusb-base-20170825 perseant-stdc-iso10646-base netbsd-8-base prg-localcount2-base3 prg-localcount2-base2 prg-localcount2-base1 prg-localcount2-base pgoyette-localcount-20170426 bouyer-socketcan-base1 jdolecek-ncq-base pgoyette-localcount-20170320
|
#
1.3 |
|
03-Mar-2017 |
palle |
branches: 1.3.12; 1.3.16; sun4v: Fixed PR 51554 - Avoid unsafe allocation in ldc/vdsk
|
Revision tags: nick-nhusb-base-20170204 bouyer-socketcan-base pgoyette-localcount-20170107 nick-nhusb-base-20161204 pgoyette-localcount-20161104 nick-nhusb-base-20161004 localcount-20160914
|
#
1.2 |
|
20-Aug-2016 |
nakayama |
branches: 1.2.2; 1.2.4; 1.2.6; Avoid "cast to pointer from integer of different size" warning on 32-bit kernels.
|
#
1.1 |
|
19-Aug-2016 |
palle |
sun4v: vdsk and ldc drivers - from OpenBSD, but heavily adapted to NetBSD scsipi - access to a virtual disk served from a ldom primary domain now works
|
#
1.7 |
|
25-Jun-2021 |
palle |
sun4v: vdsk - restart the ldc state machine when the ldc endpoint resets the link or a DATA/NACK/DRING_DATA message is received. These changes make the driver more robust. In a ldom with Solaris 11.4 SRU30 as primary domain (T5 host system) frequent resets and NACK messages are observed.
|
Revision tags: cjep_sun2x-base1 cjep_sun2x-base cjep_staticlib_x-base1 cjep_staticlib_x-base thorpej-i2c-spi-conf-base
|
#
1.6 |
|
24-Apr-2021 |
thorpej |
Merge thorpej-cfargs branch:
Simplify and make extensible the config_search() / config_found() / config_attach() interfaces: rather than having different variants for which arguments you want pass along, just have a single call that takes a variadic list of tag-value arguments.
Adjust all call sites: - Simplify wherever possible; don't pass along arguments that aren't actually needed. - Don't be explicit about what interface attribute is attaching if the device only has one. (More simplification.) - Add a config_probe() function to be used in indirect configuiration situations, making is visibly easier to see when indirect config is in play, and allowing for future change in semantics. (As of now, this is just a wrapper around config_match(), but that is an implementation detail.)
Remove unnecessary or redundant interface attributes where they're not needed.
There are currently 5 "cfargs" defined: - CFARG_SUBMATCH (submatch function for direct config) - CFARG_SEARCH (search function for indirect config) - CFARG_IATTR (interface attribte) - CFARG_LOCATORS (locators array) - CFARG_DEVHANDLE (devhandle_t - wraps OFW, ACPI, etc. handles)
...and a sentinel value CFARG_EOL.
Add some extra sanity checking to ensure that interface attributes aren't ambiguous.
Use CFARG_DEVHANDLE in MI FDT, OFW, and ACPI code, and macppc and shark ports to associate those device handles with device_t instance. This will trickle trough to more places over time (need back-end for pre-OFW Sun OBP; any others?).
|
Revision tags: thorpej-cfargs-base thorpej-futex-base bouyer-xenpvh-base2 phil-wifi-20200421 bouyer-xenpvh-base1 phil-wifi-20200411 bouyer-xenpvh-base is-mlppp-base phil-wifi-20200406 ad-namecache-base3 ad-namecache-base2 ad-namecache-base1 ad-namecache-base
|
#
1.5 |
|
19-Nov-2019 |
palle |
branches: 1.5.10; sun4v: added support for handling of opcode SCSI_MAINTENANCE_IN when using ldom based virtual disk
|
Revision tags: phil-wifi-20191119
|
#
1.4 |
|
01-Oct-2019 |
chs |
in many device attach paths, allocate memory with KM_SLEEP instead of KM_NOSLEEP and remove code to handle failures that can no longer happen.
|
Revision tags: netbsd-9-2-RELEASE netbsd-9-1-RELEASE netbsd-8-2-RELEASE netbsd-9-0-RELEASE netbsd-9-0-RC2 netbsd-9-0-RC1 netbsd-9-base phil-wifi-20190609 netbsd-8-1-RELEASE netbsd-8-1-RC1 isaki-audio2-base pgoyette-compat-merge-20190127 pgoyette-compat-20190127 pgoyette-compat-20190118 pgoyette-compat-1226 pgoyette-compat-1126 pgoyette-compat-1020 pgoyette-compat-0930 pgoyette-compat-0906 pgoyette-compat-0728 netbsd-8-0-RELEASE phil-wifi-base pgoyette-compat-0625 netbsd-8-0-RC2 pgoyette-compat-0521 pgoyette-compat-0502 pgoyette-compat-0422 netbsd-8-0-RC1 pgoyette-compat-0415 pgoyette-compat-0407 pgoyette-compat-0330 pgoyette-compat-0322 pgoyette-compat-0315 pgoyette-compat-base tls-maxphys-base-20171202 matt-nb8-mediatek-base nick-nhusb-base-20170825 perseant-stdc-iso10646-base netbsd-8-base prg-localcount2-base3 prg-localcount2-base2 prg-localcount2-base1 prg-localcount2-base pgoyette-localcount-20170426 bouyer-socketcan-base1 jdolecek-ncq-base pgoyette-localcount-20170320
|
#
1.3 |
|
03-Mar-2017 |
palle |
branches: 1.3.12; 1.3.16; sun4v: Fixed PR 51554 - Avoid unsafe allocation in ldc/vdsk
|
Revision tags: nick-nhusb-base-20170204 bouyer-socketcan-base pgoyette-localcount-20170107 nick-nhusb-base-20161204 pgoyette-localcount-20161104 nick-nhusb-base-20161004 localcount-20160914
|
#
1.2 |
|
20-Aug-2016 |
nakayama |
branches: 1.2.2; 1.2.4; 1.2.6; Avoid "cast to pointer from integer of different size" warning on 32-bit kernels.
|
#
1.1 |
|
19-Aug-2016 |
palle |
sun4v: vdsk and ldc drivers - from OpenBSD, but heavily adapted to NetBSD scsipi - access to a virtual disk served from a ldom primary domain now works
|
#
1.6 |
|
24-Apr-2021 |
thorpej |
Merge thorpej-cfargs branch:
Simplify and make extensible the config_search() / config_found() / config_attach() interfaces: rather than having different variants for which arguments you want pass along, just have a single call that takes a variadic list of tag-value arguments.
Adjust all call sites: - Simplify wherever possible; don't pass along arguments that aren't actually needed. - Don't be explicit about what interface attribute is attaching if the device only has one. (More simplification.) - Add a config_probe() function to be used in indirect configuiration situations, making is visibly easier to see when indirect config is in play, and allowing for future change in semantics. (As of now, this is just a wrapper around config_match(), but that is an implementation detail.)
Remove unnecessary or redundant interface attributes where they're not needed.
There are currently 5 "cfargs" defined: - CFARG_SUBMATCH (submatch function for direct config) - CFARG_SEARCH (search function for indirect config) - CFARG_IATTR (interface attribte) - CFARG_LOCATORS (locators array) - CFARG_DEVHANDLE (devhandle_t - wraps OFW, ACPI, etc. handles)
...and a sentinel value CFARG_EOL.
Add some extra sanity checking to ensure that interface attributes aren't ambiguous.
Use CFARG_DEVHANDLE in MI FDT, OFW, and ACPI code, and macppc and shark ports to associate those device handles with device_t instance. This will trickle trough to more places over time (need back-end for pre-OFW Sun OBP; any others?).
|
Revision tags: thorpej-cfargs-base thorpej-futex-base bouyer-xenpvh-base2 phil-wifi-20200421 bouyer-xenpvh-base1 phil-wifi-20200411 bouyer-xenpvh-base is-mlppp-base phil-wifi-20200406 ad-namecache-base3 ad-namecache-base2 ad-namecache-base1 ad-namecache-base
|
#
1.5 |
|
19-Nov-2019 |
palle |
branches: 1.5.10; sun4v: added support for handling of opcode SCSI_MAINTENANCE_IN when using ldom based virtual disk
|
Revision tags: phil-wifi-20191119
|
#
1.4 |
|
01-Oct-2019 |
chs |
in many device attach paths, allocate memory with KM_SLEEP instead of KM_NOSLEEP and remove code to handle failures that can no longer happen.
|
Revision tags: netbsd-9-1-RELEASE netbsd-8-2-RELEASE netbsd-9-0-RELEASE netbsd-9-0-RC2 netbsd-9-0-RC1 netbsd-9-base phil-wifi-20190609 netbsd-8-1-RELEASE netbsd-8-1-RC1 isaki-audio2-base pgoyette-compat-merge-20190127 pgoyette-compat-20190127 pgoyette-compat-20190118 pgoyette-compat-1226 pgoyette-compat-1126 pgoyette-compat-1020 pgoyette-compat-0930 pgoyette-compat-0906 pgoyette-compat-0728 netbsd-8-0-RELEASE phil-wifi-base pgoyette-compat-0625 netbsd-8-0-RC2 pgoyette-compat-0521 pgoyette-compat-0502 pgoyette-compat-0422 netbsd-8-0-RC1 pgoyette-compat-0415 pgoyette-compat-0407 pgoyette-compat-0330 pgoyette-compat-0322 pgoyette-compat-0315 pgoyette-compat-base tls-maxphys-base-20171202 matt-nb8-mediatek-base nick-nhusb-base-20170825 perseant-stdc-iso10646-base netbsd-8-base prg-localcount2-base3 prg-localcount2-base2 prg-localcount2-base1 prg-localcount2-base pgoyette-localcount-20170426 bouyer-socketcan-base1 jdolecek-ncq-base pgoyette-localcount-20170320
|
#
1.3 |
|
03-Mar-2017 |
palle |
branches: 1.3.12; 1.3.16; sun4v: Fixed PR 51554 - Avoid unsafe allocation in ldc/vdsk
|
Revision tags: nick-nhusb-base-20170204 bouyer-socketcan-base pgoyette-localcount-20170107 nick-nhusb-base-20161204 pgoyette-localcount-20161104 nick-nhusb-base-20161004 localcount-20160914
|
#
1.2 |
|
20-Aug-2016 |
nakayama |
branches: 1.2.2; 1.2.4; 1.2.6; Avoid "cast to pointer from integer of different size" warning on 32-bit kernels.
|
#
1.1 |
|
19-Aug-2016 |
palle |
sun4v: vdsk and ldc drivers - from OpenBSD, but heavily adapted to NetBSD scsipi - access to a virtual disk served from a ldom primary domain now works
|
#
1.5 |
|
19-Nov-2019 |
palle |
sun4v: added support for handling of opcode SCSI_MAINTENANCE_IN when using ldom based virtual disk
|
Revision tags: phil-wifi-20191119
|
#
1.4 |
|
01-Oct-2019 |
chs |
in many device attach paths, allocate memory with KM_SLEEP instead of KM_NOSLEEP and remove code to handle failures that can no longer happen.
|
Revision tags: netbsd-9-base phil-wifi-20190609 netbsd-8-1-RELEASE netbsd-8-1-RC1 isaki-audio2-base pgoyette-compat-merge-20190127 pgoyette-compat-20190127 pgoyette-compat-20190118 pgoyette-compat-1226 pgoyette-compat-1126 pgoyette-compat-1020 pgoyette-compat-0930 pgoyette-compat-0906 pgoyette-compat-0728 netbsd-8-0-RELEASE phil-wifi-base pgoyette-compat-0625 netbsd-8-0-RC2 pgoyette-compat-0521 pgoyette-compat-0502 pgoyette-compat-0422 netbsd-8-0-RC1 pgoyette-compat-0415 pgoyette-compat-0407 pgoyette-compat-0330 pgoyette-compat-0322 pgoyette-compat-0315 pgoyette-compat-base tls-maxphys-base-20171202 matt-nb8-mediatek-base nick-nhusb-base-20170825 perseant-stdc-iso10646-base netbsd-8-base prg-localcount2-base3 prg-localcount2-base2 prg-localcount2-base1 prg-localcount2-base pgoyette-localcount-20170426 bouyer-socketcan-base1 jdolecek-ncq-base pgoyette-localcount-20170320
|
#
1.3 |
|
03-Mar-2017 |
palle |
branches: 1.3.12; sun4v: Fixed PR 51554 - Avoid unsafe allocation in ldc/vdsk
|
Revision tags: nick-nhusb-base-20170204 bouyer-socketcan-base pgoyette-localcount-20170107 nick-nhusb-base-20161204 pgoyette-localcount-20161104 nick-nhusb-base-20161004 localcount-20160914
|
#
1.2 |
|
20-Aug-2016 |
nakayama |
branches: 1.2.2; 1.2.4; 1.2.6; Avoid "cast to pointer from integer of different size" warning on 32-bit kernels.
|
#
1.1 |
|
19-Aug-2016 |
palle |
sun4v: vdsk and ldc drivers - from OpenBSD, but heavily adapted to NetBSD scsipi - access to a virtual disk served from a ldom primary domain now works
|
#
1.4 |
|
01-Oct-2019 |
chs |
in many device attach paths, allocate memory with KM_SLEEP instead of KM_NOSLEEP and remove code to handle failures that can no longer happen.
|
Revision tags: netbsd-9-base phil-wifi-20190609 netbsd-8-1-RELEASE netbsd-8-1-RC1 isaki-audio2-base pgoyette-compat-merge-20190127 pgoyette-compat-20190127 pgoyette-compat-20190118 pgoyette-compat-1226 pgoyette-compat-1126 pgoyette-compat-1020 pgoyette-compat-0930 pgoyette-compat-0906 pgoyette-compat-0728 netbsd-8-0-RELEASE phil-wifi-base pgoyette-compat-0625 netbsd-8-0-RC2 pgoyette-compat-0521 pgoyette-compat-0502 pgoyette-compat-0422 netbsd-8-0-RC1 pgoyette-compat-0415 pgoyette-compat-0407 pgoyette-compat-0330 pgoyette-compat-0322 pgoyette-compat-0315 pgoyette-compat-base tls-maxphys-base-20171202 matt-nb8-mediatek-base nick-nhusb-base-20170825 perseant-stdc-iso10646-base netbsd-8-base prg-localcount2-base3 prg-localcount2-base2 prg-localcount2-base1 prg-localcount2-base pgoyette-localcount-20170426 bouyer-socketcan-base1 jdolecek-ncq-base pgoyette-localcount-20170320
|
#
1.3 |
|
03-Mar-2017 |
palle |
branches: 1.3.12; sun4v: Fixed PR 51554 - Avoid unsafe allocation in ldc/vdsk
|
Revision tags: nick-nhusb-base-20170204 bouyer-socketcan-base pgoyette-localcount-20170107 nick-nhusb-base-20161204 pgoyette-localcount-20161104 nick-nhusb-base-20161004 localcount-20160914
|
#
1.2 |
|
20-Aug-2016 |
nakayama |
branches: 1.2.2; 1.2.4; 1.2.6; Avoid "cast to pointer from integer of different size" warning on 32-bit kernels.
|
#
1.1 |
|
19-Aug-2016 |
palle |
sun4v: vdsk and ldc drivers - from OpenBSD, but heavily adapted to NetBSD scsipi - access to a virtual disk served from a ldom primary domain now works
|
#
1.3 |
|
03-Mar-2017 |
palle |
sun4v: Fixed PR 51554 - Avoid unsafe allocation in ldc/vdsk
|
Revision tags: nick-nhusb-base-20170204 bouyer-socketcan-base pgoyette-localcount-20170107 nick-nhusb-base-20161204 pgoyette-localcount-20161104 nick-nhusb-base-20161004 localcount-20160914
|
#
1.2 |
|
20-Aug-2016 |
nakayama |
branches: 1.2.2; 1.2.4; Avoid "cast to pointer from integer of different size" warning on 32-bit kernels.
|
#
1.1 |
|
19-Aug-2016 |
palle |
sun4v: vdsk and ldc drivers - from OpenBSD, but heavily adapted to NetBSD scsipi - access to a virtual disk served from a ldom primary domain now works
|
Revision tags: nick-nhusb-base-20161204 pgoyette-localcount-20161104 nick-nhusb-base-20161004 localcount-20160914
|
#
1.2 |
|
20-Aug-2016 |
nakayama |
branches: 1.2.2; 1.2.4; Avoid "cast to pointer from integer of different size" warning on 32-bit kernels.
|
#
1.1 |
|
19-Aug-2016 |
palle |
sun4v: vdsk and ldc drivers - from OpenBSD, but heavily adapted to NetBSD scsipi - access to a virtual disk served from a ldom primary domain now works
|