# 80ef351c 30-Nov-2021 Dmitry Osipenko <digetx@gmail.com>

soc/tegra: regulators: Prepare for suspend

Depending on hardware version, Tegra SoC may require a higher voltages
during resume from system suspend, otherwise hardware will crash. Set
SoC voltages to a nominal levels during suspend.

Link: https://lore.kernel.org/all/a8280b5b-7347-8995-c97b-10b798cdf057@gmail.com/
Reviewed-by: Ulf Hansson <ulf.hansson@linaro.org>
Signed-off-by: Dmitry Osipenko <digetx@gmail.com>
Signed-off-by: Thierry Reding <treding@nvidia.com>


# 029f7e24 31-May-2021 Dmitry Osipenko <digetx@gmail.com>

soc/tegra: regulators: Support core domain state syncing

The core voltage shall not drop until state of core domain is synced,
i.e. all device drivers that use core domain are loaded and ready.

Support core domain state syncing. The core domain driver invokes the
core-regulator voltage syncing once the state of domain is synced, at
this point the core voltage is allowed to go lower than the level left
after bootloader.

Tested-by: Peter Geis <pgwipeout@gmail.com> # Ouya T30
Tested-by: Paul Fertser <fercerpav@gmail.com> # PAZ00 T20
Tested-by: Nicolas Chauvet <kwizart@gmail.com> # PAZ00 T20 and TK1 T124
Tested-by: Matt Merhar <mattmerhar@protonmail.com> # Ouya T30
Reviewed-by: Ulf Hansson <ulf.hansson@linaro.org>
Signed-off-by: Dmitry Osipenko <digetx@gmail.com>
Signed-off-by: Thierry Reding <treding@nvidia.com>


# 03978d42 27-May-2021 Dmitry Osipenko <digetx@gmail.com>

soc/tegra: regulators: Bump voltages on system reboot

Ensure that SoC voltages are at a level suitable for a system reboot.
This is important for some devices that use CPU reset method for the
rebooting. SoC CPU and core voltages now are be restored to a level
that is suitable for rebooting. This patch fixes hang on reboot on
Asus Transformer TF101, it was also reported as fixing some of reboot
issues on Toshiba AC100.

Reported-by: Nikola Milosavljević <mnidza@outlook.com>
Tested-by: Nikola Milosavljević <mnidza@outlook.com> # TF101
Signed-off-by: Dmitry Osipenko <digetx@gmail.com>
Signed-off-by: Thierry Reding <treding@nvidia.com>


# ef85bb58 02-Mar-2021 Dmitry Osipenko <digetx@gmail.com>

soc/tegra: regulators: Fix locking up when voltage-spread is out of range

Fix voltage coupler lockup which happens when voltage-spread is out
of range due to a bug in the code. The max-spread requirement shall be
accounted when CPU regulator doesn't have consumers. This problem is
observed on Tegra30 Ouya game console once system-wide DVFS is enabled
in a device-tree.

Fixes: 783807436f36 ("soc/tegra: regulators: Add regulators coupler for Tegra30")
Cc: stable@vger.kernel.org
Reported-by: Peter Geis <pgwipeout@gmail.com>
Tested-by: Peter Geis <pgwipeout@gmail.com> # Ouya T30
Tested-by: Matt Merhar <mattmerhar@protonmail.com> # Ouya T30
Signed-off-by: Dmitry Osipenko <digetx@gmail.com>
Signed-off-by: Thierry Reding <treding@nvidia.com>


# 45f019a6 18-Dec-2019 Dmitry Osipenko <digetx@gmail.com>

soc/tegra: regulators: Do nothing if voltage is unchanged

There is no need to re-apply the same voltage. This change is just a minor
cleanup.

Signed-off-by: Dmitry Osipenko <digetx@gmail.com>
Signed-off-by: Thierry Reding <treding@nvidia.com>


# 78380743 25-Jul-2019 Dmitry Osipenko <digetx@gmail.com>

soc/tegra: regulators: Add regulators coupler for Tegra30

Add regulators coupler for Tegra30 SoCs that performs voltage balancing
of a coupled regulators and thus provides voltage scaling functionality.

There are 2 coupled regulators on all Tegra30 SoCs: CORE and CPU. The
coupled regulator voltages shall be in a range of 300mV from each other
and CORE voltage shall be higher than the CPU by N mV, where N depends
on the CPU voltage.

Signed-off-by: Dmitry Osipenko <digetx@gmail.com>
Acked-By: Peter De Schrijver <pdeschrijver@nvidia.com>
Signed-off-by: Thierry Reding <treding@nvidia.com>