History log of /linux-master/drivers/net/ethernet/intel/ice/ice_eswitch_br.h
Revision Date Author Comments
# e42c6e0c 12-Jul-2023 Michal Swiatkowski <michal.swiatkowski@linux.intel.com>

ice: implement static version of ageing

Remove fdb entries always when ageing time expired.

Allow user to set ageing time using port object attribute.

Reviewed-by: Simon Horman <simon.horman@corigine.com>
Signed-off-by: Michal Swiatkowski <michal.swiatkowski@linux.intel.com>
Signed-off-by: Wojciech Drewek <wojciech.drewek@intel.com>
Tested-by: Sujai Buvaneswaran <sujai.buvaneswaran@intel.com>
Signed-off-by: Tony Nguyen <anthony.l.nguyen@intel.com>


# 2946204b 12-Jul-2023 Michal Swiatkowski <michal.swiatkowski@linux.intel.com>

ice: implement bridge port vlan

Port VLAN in this case means push and pop VLAN action on specific vid.
There are a few limitation in hardware:
- push and pop can't be used separately
- if port VLAN is used there can't be any trunk VLANs, because pop
action is done on all traffic received by VSI in port VLAN mode
- port VLAN mode on uplink port isn't supported

Reflect these limitations in code using dev_info to inform the user
about unsupported configuration.

In bridge mode there is a need to configure port vlan without resetting
VFs. To do that implement ice_port_vlan_on/off() functions. They are
only configuring correct vlan_ops to allow setting port vlan.

We also need to clear port vlan without resetting the VF which is not
supported right now. Change it by implementing clear_port_vlan ops.
As previous VLAN configuration isn't always the same, store current
config while creating port vlan and restore it in clear function.

Configuration steps:
- configure switchdev with bridge
- #bridge vlan add dev eth0 vid 120 pvid untagged
- #bridge vlan add dev eth1 vid 120 pvid untagged
- ping from VF0 to VF1

Reviewed-by: Simon Horman <simon.horman@corigine.com>
Signed-off-by: Michal Swiatkowski <michal.swiatkowski@linux.intel.com>
Signed-off-by: Wojciech Drewek <wojciech.drewek@intel.com>
Tested-by: Sujai Buvaneswaran <sujai.buvaneswaran@intel.com>
Signed-off-by: Tony Nguyen <anthony.l.nguyen@intel.com>


# e9dda2cf 12-Jul-2023 Marcin Szycik <marcin.szycik@intel.com>

ice: Add VLAN FDB support in switchdev mode

Add support for matching on VLAN tag in bridge offloads.
Currently only trunk mode is supported.

To enable VLAN filtering (existing FDB entries will be deleted):
ip link set $BR type bridge vlan_filtering 1

To add VLANs to bridge in trunk mode:
bridge vlan add dev $PF1 vid 110-111
bridge vlan add dev $VF1_PR vid 110-111

Signed-off-by: Marcin Szycik <marcin.szycik@intel.com>
Signed-off-by: Wojciech Drewek <wojciech.drewek@intel.com>
Tested-by: Sujai Buvaneswaran <sujai.buvaneswaran@intel.com>
Signed-off-by: Tony Nguyen <anthony.l.nguyen@intel.com>


# bccd9bce 12-Jul-2023 Marcin Szycik <marcin.szycik@intel.com>

ice: Add guard rule when creating FDB in switchdev

Introduce new "guard" rule upon FDB entry creation.

It matches on src_mac, has valid bit unset, allow_pass_l2 set
and has a nop action.

Previously introduced "forward" rule matches on dst_mac, has valid
bit set, need_pass_l2 set and has a forward action.

With these rules, a packet will be offloaded only if FDB exists in both
directions (RX and TX).

Let's assume link partner sends a packet to VF1: src_mac = LP_MAC,
dst_mac = is VF1_MAC. Bridge adds FDB, two rules are created:
1. Guard rule matching on src_mac == LP_MAC
2. Forward rule matching on dst_mac == LP_MAC
Now VF1 responds with src_mac = VF1_MAC, dst_mac = LP_MAC. Before this
change, only one rule with dst_mac == LP_MAC would have existed, and the
packet would have been offloaded, meaning the bridge wouldn't add FDB in
the opposite direction. Now, the forward rule matches (dst_mac == LP_MAC),
but it has need_pass_l2 set an there is no guard rule with
src_mac == VF1_MAC, so the packet goes through slow-path and the bridge
adds FDB. Two rules are created:
1. Guard rule matching on src_mac == VF1_MAC
2. Forward rule matching on dst_mac == VF1_MAC
Further packets in both directions will be offloaded.

The same example is true in opposite direction (i.e. VF1 is the first to
send a packet out).

Reviewed-by: Simon Horman <simon.horman@corigine.com>
Signed-off-by: Marcin Szycik <marcin.szycik@intel.com>
Signed-off-by: Wojciech Drewek <wojciech.drewek@intel.com>
Tested-by: Sujai Buvaneswaran <sujai.buvaneswaran@intel.com>
Signed-off-by: Tony Nguyen <anthony.l.nguyen@intel.com>


# 7c945a1a 12-Jul-2023 Wojciech Drewek <wojciech.drewek@intel.com>

ice: Switchdev FDB events support

Listen for SWITCHDEV_FDB_{ADD|DEL}_TO_DEVICE events while in switchdev
mode. Accept these events on both uplink and VF PR ports. Add HW
rules in newly created workqueue. FDB entries are stored in rhashtable
for lookup when removing the entry and in the list for cleanup
purpose. Direction of the HW rule depends on the type of the ports
on which the FDB event was received:

ICE_ESWITCH_BR_UPLINK_PORT:
TX rule that forwards the packet to the LAN (egress).

ICE_ESWITCH_BR_VF_REPR_PORT:
RX rule that forwards the packet to the VF associated
with the port representor.

In both cases the rule matches on the dst mac address.
All the FDB entries are stored in the bridge structure.
When the port is removed all the FDB entries associated with
this port are removed as well. This is achieved thanks to the reference
to the port that FDB entry holds.

In the fwd rule we use only one lookup type (MAC address)
but lkups_cnt variable is already introduced because
we will have more lookups in the subsequent patches.

Signed-off-by: Wojciech Drewek <wojciech.drewek@intel.com>
Tested-by: Sujai Buvaneswaran <sujai.buvaneswaran@intel.com>
Signed-off-by: Tony Nguyen <anthony.l.nguyen@intel.com>


# f6e8fb55 12-Jul-2023 Wojciech Drewek <wojciech.drewek@intel.com>

ice: Implement basic eswitch bridge setup

With this patch, ice driver is able to track if the port
representors or uplink port were added to the linux bridge in
switchdev mode. Listen for NETDEV_CHANGEUPPER events in order to
detect this. ice_esw_br data structure reflects the linux bridge
and stores all the ports of the bridge (ice_esw_br_port) in
xarray, it's created when the first port is added to the bridge and
freed once the last port is removed. Note that only one bridge is
supported per eswitch.

Bridge port (ice_esw_br_port) can be either a VF port representor
port or uplink port (ice_esw_br_port_type). In both cases bridge port
holds a reference to the VSI, VF's VSI in case of the PR and uplink
VSI in case of the uplink. VSI's index is used as an index to the
xarray in which ports are stored.

Add a check which prevents configuring switchdev mode if uplink is
already added to any bridge. This is needed because we need to listen
for NETDEV_CHANGEUPPER events to record if the uplink was added to
the bridge. Netdevice notifier is registered after eswitch mode
is changed to switchdev.

Reviewed-by: Simon Horman <simon.horman@corigine.com>
Signed-off-by: Wojciech Drewek <wojciech.drewek@intel.com>
Tested-by: Sujai Buvaneswaran <sujai.buvaneswaran@intel.com>