#
118e10cd |
|
18-Dec-2023 |
Tianrui Zhao <zhaotianrui@loongson.cn> |
LoongArch: KVM: Add LASX (256bit SIMD) support This patch adds LASX (256bit SIMD) support for LoongArch KVM. There will be LASX exception in KVM when guest use the LASX instructions. KVM will enable LASX and restore the vector registers for guest and then return to guest to continue running. Reviewed-by: Bibo Mao <maobibo@loongson.cn> Signed-off-by: Tianrui Zhao <zhaotianrui@loongson.cn> Signed-off-by: Huacai Chen <chenhuacai@loongson.cn>
|
#
db1ecca2 |
|
18-Dec-2023 |
Tianrui Zhao <zhaotianrui@loongson.cn> |
LoongArch: KVM: Add LSX (128bit SIMD) support This patch adds LSX (128bit SIMD) support for LoongArch KVM. There will be LSX exception in KVM when guest use the LSX instructions. KVM will enable LSX and restore the vector registers for guest and then return to guest to continue running. Signed-off-by: Tianrui Zhao <zhaotianrui@loongson.cn> Signed-off-by: Huacai Chen <chenhuacai@loongson.cn>
|
#
7ab6fb50 |
|
18-Dec-2023 |
Bibo Mao <maobibo@loongson.cn> |
LoongArch: KVM: Optimization for memslot hugepage checking During shadow mmu page fault, there is checking for huge page for specified memslot. Page fault is hot path, check logic can be done when memslot is created. Here two flags are added for huge page checking, KVM_MEM_HUGEPAGE_CAPABLE and KVM_MEM_HUGEPAGE_INCAPABLE. Indeed for an optimized qemu, memslot for DRAM is always huge page aligned. The flag is firstly checked during hot page fault path. Now only huge page flag is supported, there is a long way for super page support in LoongArch system. Since super page size is 64G for 16K pagesize and 1G for 4K pagesize, 64G physical address is rarely used and LoongArch kernel needs support super page for 4K. Also memory layout of LoongArch qemu VM should be 1G aligned. Signed-off-by: Bibo Mao <maobibo@loongson.cn> Signed-off-by: Huacai Chen <chenhuacai@loongson.cn>
|
#
f128cf8c |
|
27-Oct-2023 |
Sean Christopherson <seanjc@google.com> |
KVM: Convert KVM_ARCH_WANT_MMU_NOTIFIER to CONFIG_KVM_GENERIC_MMU_NOTIFIER Convert KVM_ARCH_WANT_MMU_NOTIFIER into a Kconfig and select it where appropriate to effectively maintain existing behavior. Using a proper Kconfig will simplify building more functionality on top of KVM's mmu_notifier infrastructure. Add a forward declaration of kvm_gfn_range to kvm_types.h so that including arch/powerpc/include/asm/kvm_ppc.h's with CONFIG_KVM=n doesn't generate warnings due to kvm_gfn_range being undeclared. PPC defines hooks for PR vs. HV without guarding them via #ifdeffery, e.g. bool (*unmap_gfn_range)(struct kvm *kvm, struct kvm_gfn_range *range); bool (*age_gfn)(struct kvm *kvm, struct kvm_gfn_range *range); bool (*test_age_gfn)(struct kvm *kvm, struct kvm_gfn_range *range); bool (*set_spte_gfn)(struct kvm *kvm, struct kvm_gfn_range *range); Alternatively, PPC could forward declare kvm_gfn_range, but there's no good reason not to define it in common KVM. Acked-by: Anup Patel <anup@brainfault.org> Signed-off-by: Sean Christopherson <seanjc@google.com> Reviewed-by: Paolo Bonzini <pbonzini@redhat.com> Reviewed-by: Fuad Tabba <tabba@google.com> Tested-by: Fuad Tabba <tabba@google.com> Message-Id: <20231027182217.3615211-8-seanjc@google.com> Signed-off-by: Paolo Bonzini <pbonzini@redhat.com>
|
#
b37e6b68 |
|
01-Oct-2023 |
Tianrui Zhao <zhaotianrui@loongson.cn> |
LoongArch: KVM: Add kvm related header files Add LoongArch KVM related header files, including kvm.h, kvm_host.h and kvm_types.h. All of those are about LoongArch virtualization features and kvm interfaces. Reviewed-by: Bibo Mao <maobibo@loongson.cn> Tested-by: Huacai Chen <chenhuacai@loongson.cn> Signed-off-by: Tianrui Zhao <zhaotianrui@loongson.cn> Signed-off-by: Huacai Chen <chenhuacai@loongson.cn>
|