# 2baee0c5 11-Dec-2019 Benoit Parrot <bparrot@ti.com>

ARM: OMAP: DRA7xx: Make CAM clock domain SWSUP only

Both CAL and VIP rely on this clock domain. But CAL DPHY require
LVDSRX_96M_GFCLK to be active. When this domain is set to HWSUP the
LVDSRX_96M_GFCLK is on;y active when VIP1 clock is also active. If only
CAL on DRA72x (which uses the VIP2 clkctrl) probes the CAM domain is
enabled but the LVDSRX_96M_GFCLK is left gated. Since LVDSRX_96M_GFCLK
is sourcing the input clock to the DPHY then actual frame capture cannot
start as the phy are inactive.

So we either have to also enabled VIP1 even if we don't intend on using
it or we need to set the CAM domain to use SWSUP only.

This patch implements the latter.

Signed-off-by: Benoit Parrot <bparrot@ti.com>
Acked-by: Tony Lindgren <tony@atomide.com>
Signed-off-by: Tony Lindgren <tony@atomide.com>


# d2912cb1 04-Jun-2019 Thomas Gleixner <tglx@linutronix.de>

treewide: Replace GPLv2 boilerplate/reference with SPDX - rule 500

Based on 2 normalized pattern(s):

this program is free software you can redistribute it and or modify
it under the terms of the gnu general public license version 2 as
published by the free software foundation

this program is free software you can redistribute it and or modify
it under the terms of the gnu general public license version 2 as
published by the free software foundation #

extracted by the scancode license scanner the SPDX license identifier

GPL-2.0-only

has been chosen to replace the boilerplate/reference in 4122 file(s).

Signed-off-by: Thomas Gleixner <tglx@linutronix.de>
Reviewed-by: Enrico Weigelt <info@metux.net>
Reviewed-by: Kate Stewart <kstewart@linuxfoundation.org>
Reviewed-by: Allison Randal <allison@lohutok.net>
Cc: linux-spdx@vger.kernel.org
Link: https://lkml.kernel.org/r/20190604081206.933168790@linutronix.de
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>


# 2c949ce3 27-Mar-2017 Kishon Vijay Abraham I <kishon@ti.com>

ARM: DRA7: clockdomain: Change the CLKTRCTRL of CM_PCIE_CLKSTCTRL to SW_WKUP

The PCIe programming sequence in TRM suggests CLKSTCTRL of PCIe should be
set to SW_WKUP. There are no issues when CLKSTCTRL is set to HW_AUTO in RC
mode. However in EP mode, the host system is not able to access the
MEMSPACE and setting the CLKSTCTRL to SW_WKUP fixes it.

Acked-by: Tony Lindgren <tony@atomide.com>
Signed-off-by: Kishon Vijay Abraham I <kishon@ti.com>
Signed-off-by: Bjorn Helgaas <bhelgaas@google.com>


# c2ce5fb3 18-Oct-2016 Joel Fernandes <joelf@ti.com>

ARM: OMAP: DRA7xx: Make L4SEC clock domain SWSUP only

Using HWSUP for l4sec clock domain is causing warnings in HWMOD code for
DRA7. Based on some observations, once the clock domain goes into an IDLE
state (because of no activity etc), the IDLEST for the module goes to '0x2'
value which means Interface IDLE condition. So far so go, however once the
MODULEMODE is set to disabled for the particular IP, the IDLEST for the
module should go to '0x3', per the HW AUTO IDLE protocol. However this is
not observed and there is no reason per the protocl for the transition to
not happen. This could potentially be a bug in the HW AUTO state-machine.

Work around for this is to use SWSUP only for the particular clockdomain.
With this all the transitions of IDLEST happen correctly and warnings
don't occur.

Signed-off-by: Joel Fernandes <joelf@ti.com>
Signed-off-by: Lokesh Vutla <lokeshvutla@ti.com>
Signed-off-by: Tero Kristo <t-kristo@ti.com>
Signed-off-by: Tony Lindgren <tony@atomide.com>


# 1cbabcb9 05-Apr-2016 Keerthy <j-keerthy@ti.com>

ARM: DRA7: clockdomain: Implement timer workaround for errata i874

Errata Title:
i874: TIMER5/6/7/8 interrupts not propagated

Description:
When TIMER5, TIMER6, TIMER7, or TIMER8 clocks are enabled
(CM_IPU_TIMER5/6/7/8_CLKCTRL[0:1]MODULEMODE=0x2:ENABLE) and the CD-IPU
is in HW_AUTO mode (CM_IPU_CLKSTCTRL[0:1]CLKTRCTRL=0x3:HW_AUTO) the
corresponding TIMER will continue counting, but enabled interrupts
will not be propagated to the destinations (MPU, DSP, etc) in the
SoC until the TIMER registers are accessed from the CPUs (MPU, DSP
etc.). This can result in missed timer interrupts.

Workaround:
In order for TIMER5/6/7/8 interrupts to be propagated and serviced
correctly the CD_IPU domain should be set to SW_WKUP mode
(CM_IPU_CLKSTCTRL[0:1]CLKTRCTRL=0x2:SW_WKUP).

The above workaround is achieved by switching the IPU clockdomain
flags from HWSUP_SWSUP to SWSUP only.

Signed-off-by: Keerthy <j-keerthy@ti.com>
Signed-off-by: Suman Anna <s-anna@ti.com>
Signed-off-by: Paul Walmsley <paul@pwsan.com>


# b9e23f32 03-Jun-2015 Vignesh R <vigneshr@ti.com>

ARM: OMAP2+: DRA7: clockdomain: change l4per2_7xx_clkdm to SW_WKUP

Legacy IPs like PWMSS, present under l4per2_7xx_clkdm, cannot support
smart-idle when its clock domain is in HW_AUTO on DRA7 SoCs. Hence,
program clock domain to SW_WKUP.

Signed-off-by: Vignesh R <vigneshr@ti.com>
Acked-by: Tero Kristo <t-kristo@ti.com>
Reviewed-by: Paul Walmsley <paul@pwsan.com>
Signed-off-by: Paul Walmsley <paul@pwsan.com>
Cc: <stable@vger.kernel.org>


# 11fadcfa 09-Jul-2013 Ambresh K <ambresh@ti.com>

ARM: OMAP: DRA7: clockdomain: Add DRA7XX data and update header

Add the data file to describe all clock domains inside the DRA7XX SoC

Signed-off-by: Ambresh K <ambresh@ti.com>
Signed-off-by: Tero Kristo <t-kristo@ti.com>
Signed-off-by: Rajendra Nayak <rnayak@ti.com>
[paul@pwsan.com: added generation notation to comments]
Signed-off-by: Paul Walmsley <paul@pwsan.com>