339853 |
|
29-Oct-2018 |
hselasky |
MFC r339587: Added support for formula-based arbitrary baud rates, in contrast to the current fixed values, which enables use of rates above 1 Mbps. Improved the detection of HXD chips, and the status flag handling as well.
Submitted by: Gabor Simon <gabor.simon75@gmail.com> PR: 225932 Differential revision: https://reviews.freebsd.org/D16639 Sponsored by: Mellanox Technologies
|
#
305557 |
|
07-Sep-2016 |
dim |
MFC r305388:
With clang 3.9.0, compiling uplcom results in the following warnings:
sys/dev/usb/serial/uplcom.c:543:29: error: implicit conversion from 'int' to 'int8_t' (aka 'signed char') changes value from 192 to -64 [-Werror,-Wconstant-conversion] if (uplcom_pl2303_do(udev, UT_READ_VENDOR_DEVICE, UPLCOM_SET_REQUEST, 0x8484, 0, 1) ~~~~~~~~~~~~~~~~ ^~~~~~~~~~~~~~~~~~~~~ sys/dev/usb/usb.h:179:53: note: expanded from macro 'UT_READ_VENDOR_DEVICE' #define UT_READ_VENDOR_DEVICE (UT_READ | UT_VENDOR | UT_DEVICE) ~~~~~~~~~~~~~~~~~~~~~^~~~~~~~~~~
This is because UT_READ is 0x80, so the int8_t argument is wrapped to a negative value. Fix this by using uint8_t instead.
Reviewed by: imp, hselasky Differential Revision: https://reviews.freebsd.org/D7776
|