/netgear-WNDR4500v2-V1.0.0.60_1.0.38/src/linux/linux-2.6/include/asm-ia64/ |
H A D | sal.h | 653 struct ia64_sal_retval isrv; local 655 SAL_CALL(isrv, SAL_FREQ_BASE, which, 0, 0, 0, 0, 0, 0); 656 *ticks_per_second = isrv.v0; 657 *drift_info = isrv.v1; 658 return isrv.status; 668 struct ia64_sal_retval isrv; local 669 SAL_CALL(isrv, SAL_CACHE_INIT, 0, 0, 0, 0, 0, 0, 0); 670 return isrv.status; 680 struct ia64_sal_retval isrv; local 681 SAL_CALL_REENTRANT(isrv, SAL_CLEAR_STATE_INF 693 struct ia64_sal_retval isrv; local 709 struct ia64_sal_retval isrv; local 725 struct ia64_sal_retval isrv; local 740 struct ia64_sal_retval isrv; local 750 struct ia64_sal_retval isrv; local 761 struct ia64_sal_retval isrv; local 774 struct ia64_sal_retval isrv; local 790 struct ia64_sal_retval isrv; local 803 struct ia64_sal_retval isrv; local 817 struct ia64_sal_retval isrv; local [all...] |
/netgear-WNDR4500v2-V1.0.0.60_1.0.38/src/linux/linux-2.6/arch/ia64/kernel/ |
H A D | sal.c | 231 struct ia64_sal_retval isrv; local 246 SAL_CALL(isrv, SAL_CACHE_FLUSH, cache_type, 0, 0, 0, 0, 0, 0); 248 if (isrv.status) 249 printk(KERN_ERR "SAL_CAL_FLUSH failed with %ld\n", isrv.status); 269 struct ia64_sal_retval isrv; local 284 SAL_CALL(isrv, SAL_CACHE_FLUSH, cache_type, 0, 0, 0, 0, 0, 0); 285 return isrv.status;
|
H A D | mca.c | 567 struct ia64_sal_retval isrv; local 569 isrv = ia64_sal_mc_set_params(SAL_MC_PARAM_CPE_INT, SAL_MC_PARAM_MECHANISM_INT, cpev, 0, 0); 570 if (isrv.status) { 572 "Error interrupt vector with SAL (status %ld)\n", isrv.status); 1768 struct ia64_sal_retval isrv; local 1787 isrv = ia64_sal_mc_set_params(SAL_MC_PARAM_RENDEZ_INT, 1792 rc = isrv.status; 1797 "%ld to %ld milliseconds\n", timeout, isrv.v0); 1798 timeout = isrv.v0; 1808 isrv [all...] |
/netgear-WNDR4500v2-V1.0.0.60_1.0.38/src/linux/linux-2.6/include/asm-ia64/sn/ |
H A D | sn_sal.h | 489 struct ia64_sal_retval isrv; local 490 SAL_CALL_REENTRANT(isrv, SN_SAL_POD_MODE, 0, 0, 0, 0, 0, 0, 0); 491 if (isrv.status) 493 return isrv.v0; 517 struct ia64_sal_retval isrv; local 519 SAL_CALL(isrv, SN_SAL_PROBE, addr, size, 0, 0, 0, 0, 0); 524 *((u8*)data_ptr) = (u8)isrv.v0; 527 *((u16*)data_ptr) = (u16)isrv.v0; 530 *((u32*)data_ptr) = (u32)isrv.v0; 533 *((u64*)data_ptr) = (u64)isrv 747 struct ia64_sal_retval isrv; local 913 struct ia64_sal_retval isrv; local [all...] |
/netgear-WNDR4500v2-V1.0.0.60_1.0.38/src/linux/linux-2.6/arch/ia64/sn/pci/ |
H A D | pci_dma.c | 331 struct ia64_sal_retval isrv; local 339 SAL_CALL(isrv, SN_SAL_IOIF_PCI_SAFE, 345 if (isrv.status == 0) 377 struct ia64_sal_retval isrv; local 385 SAL_CALL(isrv, SN_SAL_IOIF_PCI_SAFE, 391 if (isrv.status == 0)
|
/netgear-WNDR4500v2-V1.0.0.60_1.0.38/src/linux/linux-2.6/arch/ia64/sn/kernel/ |
H A D | io_common.c | 130 struct ia64_sal_retval isrv = {0,0,0,0}; local 142 SAL_CALL_NOLOCK(isrv, SN_SAL_IOIF_GET_WIDGET_DMAFLUSH_LIST, 144 if (isrv.status) 146 ia64_sal_strerror(isrv.status)); 152 return isrv.status;
|
H A D | io_acpi_init.c | 47 struct ia64_sal_retval isrv = {0,0,0,0}; local 49 SAL_CALL_NOLOCK(isrv, 51 *result = isrv.v0; 52 return isrv.status;
|