Searched refs:i_nlink (Results 1 - 25 of 148) sorted by relevance

123456

/netgear-R7000-V1.0.7.12_1.2.5/components/opensource/linux/linux-2.6.36/fs/
H A Dstack.c77 dest->i_nlink = src->i_nlink;
/netgear-R7000-V1.0.7.12_1.2.5/components/opensource/linux/linux-2.6.36/fs/squashfs/
H A Dinode.c162 inode->i_nlink = 1;
206 inode->i_nlink = le32_to_cpu(sqsh_ino->nlink);
235 inode->i_nlink = le32_to_cpu(sqsh_ino->nlink);
260 inode->i_nlink = le32_to_cpu(sqsh_ino->nlink);
287 inode->i_nlink = le32_to_cpu(sqsh_ino->nlink);
328 inode->i_nlink = le32_to_cpu(sqsh_ino->nlink);
352 inode->i_nlink = le32_to_cpu(sqsh_ino->nlink);
373 inode->i_nlink = le32_to_cpu(sqsh_ino->nlink);
392 inode->i_nlink = le32_to_cpu(sqsh_ino->nlink);
/netgear-R7000-V1.0.7.12_1.2.5/components/opensource/linux/linux-2.6.36/fs/affs/
H A Dinode.c57 inode->i_nlink = 1;
135 inode->i_nlink = 2;
175 if (!inode->i_nlink)
253 pr_debug("AFFS: evict_inode(ino=%lu, nlink=%u)\n", inode->i_ino, inode->i_nlink);
256 if (!inode->i_nlink) {
275 if (!inode->i_nlink)
302 inode->i_nlink = 1;
385 inode->i_nlink = 2;
/netgear-R7000-V1.0.7.12_1.2.5/components/opensource/linux/linux-2.6.36/fs/reiserfs/
H A Dnamei.c22 #define INC_DIR_INODE_NLINK(i) if (i->i_nlink != 1) { inc_nlink(i); if (i->i_nlink >= REISERFS_LINK_MAX) i->i_nlink=1; }
23 #define DEC_DIR_INODE_NLINK(i) if (i->i_nlink != 1) drop_nlink(i);
379 if (dir->i_nlink == 0) {
623 inode->i_nlink--;
702 inode->i_nlink--;
771 dir->i_nlink--;
787 inode->i_nlink = 0;
878 if (inode->i_nlink !
[all...]
/netgear-R7000-V1.0.7.12_1.2.5/components/opensource/linux/linux-2.6.36/include/linux/
H A Dbfs_fs.h33 __le32 i_nlink; member in struct:bfs_inode
/netgear-R7000-V1.0.7.12_1.2.5/components/opensource/linux/linux-2.6.36/fs/hpfs/
H A Dinode.c58 i->i_nlink = 0;*/
82 i->i_nlink = 1;
106 i->i_nlink = 1;
130 i->i_nlink = 2 + n_subdirs;
136 i->i_nlink = 1;
192 if (!i->i_nlink) {
223 if (i->i_ino != hpfs_sb(i->i_sb)->sb_root && i->i_nlink) {
309 if (!inode->i_nlink) {
/netgear-R7000-V1.0.7.12_1.2.5/components/opensource/linux/linux-2.6.36/fs/sysv/
H A Dinode.c221 inode->i_nlink = fs16_to_cpu(sbi, raw_inode->i_nlink);
275 raw_inode->i_nlink = cpu_to_fs16(sbi, inode->i_nlink);
313 if (!inode->i_nlink) {
319 if (!inode->i_nlink)
H A Dnamei.c124 if (inode->i_nlink >= SYSV_SB(inode->i_sb)->s_link_max)
139 if (dir->i_nlink >= SYSV_SB(dir->i_sb)->s_link_max)
257 if (new_dir->i_nlink >= SYSV_SB(new_dir->i_sb)->s_link_max)
H A Dialloc.c35 /* An inode on disk is considered free if both i_mode == 0 and i_nlink == 0. */
82 if (raw_inode->i_mode == 0 && raw_inode->i_nlink == 0) {
202 if (raw_inode->i_mode == 0 && raw_inode->i_nlink == 0)
/netgear-R7000-V1.0.7.12_1.2.5/components/opensource/linux/linux-2.6.36/fs/nilfs2/
H A Dnamei.c213 if (inode->i_nlink >= NILFS_LINK_MAX)
239 if (dir->i_nlink >= NILFS_LINK_MAX)
305 if (!inode->i_nlink) {
308 inode->i_ino, inode->i_nlink);
309 inode->i_nlink = 1;
423 if (new_dir->i_nlink >= NILFS_LINK_MAX)
/netgear-R7000-V1.0.7.12_1.2.5/components/opensource/linux/linux-2.6.36/fs/jfs/
H A Dnamei.c174 ip->i_nlink = 0;
223 if (dip->i_nlink == JFS_LINK_MAX) {
294 ip->i_nlink = 2; /* for '.' */
313 ip->i_nlink = 0;
522 ASSERT(ip->i_nlink);
533 if (ip->i_nlink == 0) {
584 if (ip->i_nlink == 0)
808 if (ip->i_nlink == JFS_LINK_MAX)
811 if (ip->i_nlink == 0)
849 ip->i_nlink
[all...]
H A Dinode.c94 if (inode->i_nlink == 0 || !test_cflag(COMMIT_Dirty, inode))
116 if (inode->i_nlink && test_cflag(COMMIT_Dirty, inode))
152 if (!inode->i_nlink && !is_bad_inode(inode)) {
/netgear-R7000-V1.0.7.12_1.2.5/components/opensource/linux/linux-2.6.36/fs/minix/
H A Dnamei.c99 if (inode->i_nlink >= minix_sb(inode->i_sb)->s_link_max)
113 if (dir->i_nlink >= minix_sb(dir->i_sb)->s_link_max)
227 if (new_dir->i_nlink >= info->s_link_max)
/netgear-R7000-V1.0.7.12_1.2.5/components/opensource/linux/linux-2.6.36/fs/ext3/
H A Dialloc.c108 if (inode->i_nlink) {
110 inode->i_nlink);
424 if (!dir || !dir->i_nlink)
614 inode->i_nlink = 0;
649 * inodes that were being truncated, so we can't check i_nlink==0.
663 if (inode->i_nlink && !ext3_can_truncate(inode))
687 printk(KERN_NOTICE "i_nlink=%u\n", inode->i_nlink);
689 if (inode->i_nlink == 0)
/netgear-R7000-V1.0.7.12_1.2.5/components/opensource/linux/linux-2.6.36/fs/ocfs2/
H A Dnamei.c204 inode->i_nlink = 2;
206 inode->i_nlink = 1;
254 if (S_ISDIR(mode) && (dir->i_nlink >= ocfs2_link_max(osb))) {
532 ocfs2_set_links_count(fe, inode->i_nlink);
672 if (!dir->i_nlink) {
723 ocfs2_set_links_count(fe, inode->i_nlink);
787 if (inode->i_nlink == 2)
792 if (inode->i_nlink == 1)
863 if (inode->i_nlink != 2 || !ocfs2_empty_dir(inode)) {
923 ocfs2_set_links_count(fe, inode->i_nlink);
[all...]
/netgear-R7000-V1.0.7.12_1.2.5/components/opensource/linux/linux-2.6.36/fs/hfsplus/
H A Ddir.c250 inode->i_nlink = 0;
341 if (inode->i_nlink > 0)
345 if (!inode->i_nlink) {
377 inode->i_nlink = 0;
419 inode->i_nlink = 0;
450 inode->i_nlink = 0;
/netgear-R7000-V1.0.7.12_1.2.5/components/opensource/linux/linux-2.6.36/fs/exofs/
H A Dnamei.c151 if (inode->i_nlink >= EXOFS_LINK_MAX)
166 if (dir->i_nlink >= EXOFS_LINK_MAX)
286 if (new_dir->i_nlink >= EXOFS_LINK_MAX)
/netgear-R7000-V1.0.7.12_1.2.5/components/opensource/linux/linux-2.6.36/fs/ext2/
H A Dnamei.c202 if (inode->i_nlink >= EXT2_LINK_MAX)
226 if (dir->i_nlink >= EXT2_LINK_MAX)
356 if (new_dir->i_nlink >= EXT2_LINK_MAX)
/netgear-R7000-V1.0.7.12_1.2.5/components/opensource/linux/linux-2.6.36/fs/logfs/
H A Dinode.c92 if (err || inode->i_nlink == 0) {
93 /* inode->i_nlink == 0 can be true when called from
95 /* set i_nlink to 0 to prevent caching */
96 inode->i_nlink = 0;
195 inode->i_nlink = 1;
/netgear-R7000-V1.0.7.12_1.2.5/components/opensource/linux/linux-2.6.36/fs/ufs/
H A Dnamei.c176 if (inode->i_nlink >= UFS_LINK_MAX) {
195 if (dir->i_nlink >= UFS_LINK_MAX)
318 if (new_dir->i_nlink >= UFS_LINK_MAX)
H A Dinode.c629 inode->i_nlink = fs16_to_cpu(sb, ufs_inode->ui_nlink);
630 if (inode->i_nlink == 0) {
677 inode->i_nlink = fs16_to_cpu(sb, ufs2_inode->ui_nlink);
678 if (inode->i_nlink == 0) {
784 ufs_inode->ui_nlink = cpu_to_fs16(sb, inode->i_nlink);
817 if (!inode->i_nlink)
828 ufs_inode->ui_nlink = cpu_to_fs16(sb, inode->i_nlink);
856 if (!inode->i_nlink)
918 if (!inode->i_nlink && !is_bad_inode(inode))
/netgear-R7000-V1.0.7.12_1.2.5/components/opensource/linux/linux-2.6.36/fs/udf/
H A Dnamei.c583 inode->i_nlink--;
627 inode->i_nlink--;
664 if (dir->i_nlink >= (256 << sizeof(dir->i_nlink)) - 1)
677 inode->i_nlink--;
682 inode->i_nlink = 2;
695 inode->i_nlink = 0;
812 if (inode->i_nlink != 2)
815 inode->i_nlink);
853 if (!inode->i_nlink) {
[all...]
/netgear-R7000-V1.0.7.12_1.2.5/components/opensource/linux/linux-2.6.36/fs/ecryptfs/
H A Dinode.c541 old_dentry->d_inode->i_nlink =
542 ecryptfs_inode_to_lower(old_dentry->d_inode)->i_nlink;
566 dentry->d_inode->i_nlink =
567 ecryptfs_inode_to_lower(dentry->d_inode)->i_nlink;
632 dir->i_nlink = lower_dir_dentry->d_inode->i_nlink;
655 dir->i_nlink = lower_dir_dentry->d_inode->i_nlink;
/netgear-R7000-V1.0.7.12_1.2.5/components/opensource/linux/linux-2.6.36/fs/gfs2/
H A Dinode.c361 ip->i_inode.i_nlink = be32_to_cpu(str->di_nlink);
502 nlink = ip->i_inode.i_nlink + diff;
506 if (diff < 0 && nlink > ip->i_inode.i_nlink) {
528 if (ip->i_inode.i_nlink == 0)
630 if (!dip->i_inode.i_nlink)
646 if (S_ISDIR(mode) && dip->i_inode.i_nlink == (u32)-1)
856 ip->i_inode.i_nlink = 1;
1057 str->di_nlink = cpu_to_be32(ip->i_inode.i_nlink);
/netgear-R7000-V1.0.7.12_1.2.5/components/opensource/linux/linux-2.6.36/fs/autofs/
H A Dinode.c252 inode->i_nlink = 2;
282 inode->i_nlink = 1;

Completed in 379 milliseconds

123456