Searched refs:v_subdisks (Results 1 - 13 of 13) sorted by relevance

/freebsd-12-stable/sys/geom/raid/
H A Dtr_concat.c135 if (vol->v_subdisks[i].sd_state !=
137 size += vol->v_subdisks[i].sd_size;
239 offset >= vol->v_subdisks[no].sd_size) {
240 offset -= vol->v_subdisks[no].sd_size;
247 sd = &vol->v_subdisks[no];
307 offset >= vol->v_subdisks[no].sd_size) {
308 offset -= vol->v_subdisks[no].sd_size;
314 sd = &vol->v_subdisks[no];
316 error = g_raid_subdisk_kerneldump(&vol->v_subdisks[no],
H A Dtr_raid1e.c200 bestsd = &vol->v_subdisks[i * N];
202 sd = &vol->v_subdisks[i * N + j];
223 worstsd = &vol->v_subdisks[i * N];
225 sd = &vol->v_subdisks[i * N + j];
255 sd = &vol->v_subdisks[i];
269 bestsd = &vol->v_subdisks[i];
270 worstsd = &vol->v_subdisks[i];
272 sd = &vol->v_subdisks[(i + j) % vol->v_disks_count];
480 bp->bio_caller1 = &vol->v_subdisks[(disk + best) % vol->v_disks_count];
644 sd = &vol->v_subdisks[(n
[all...]
H A Dtr_raid0.c244 cbp->bio_caller1 = &vol->v_subdisks[no];
298 error = g_raid_subdisk_kerneldump(&vol->v_subdisks[no],
H A Dg_raid.c735 subdisk = &vol->v_subdisks[i];
759 sd = &vol->v_subdisks[i];
972 sd = &vol->v_subdisks[i];
1083 sd = &vol->v_subdisks[i];
1643 sd = &vol->v_subdisks[i];
1660 if ((disk = vol->v_subdisks[0].sd_disk) != NULL &&
1665 pp->stripeoffset = off + vol->v_subdisks[0].sd_offset;
1930 vol->v_subdisks[i].sd_softc = sc;
1931 vol->v_subdisks[i].sd_volume = vol;
1932 vol->v_subdisks[
[all...]
H A Dtr_raid1.c174 bestsd = &vol->v_subdisks[0];
176 tsd = &vol->v_subdisks[i];
498 sd = &vol->v_subdisks[i];
561 sd = &vol->v_subdisks[i];
913 sd = &vol->v_subdisks[i];
H A Dmd_promise.c564 if (vol->v_subdisks[i].sd_state != G_RAID_SUBDISK_S_NONE)
726 sd = &vol->v_subdisks[i];
731 vol->v_subdisks[i].sd_state < sd->sd_state))
761 sd = &vol->v_subdisks[disk_pos];
769 vol->v_subdisks[disk_pos].sd_disk = disk;
851 sd = &vol->v_subdisks[i];
868 sd = &vol->v_subdisks[i];
937 sd = &vol->v_subdisks[i];
1477 sd = &vol->v_subdisks[i];
1727 if (vol->v_subdisks[
[all...]
H A Dmd_intel.c1306 sd = &vol->v_subdisks[j];
1331 sd = &vol->v_subdisks[j];
1890 sd = &vol->v_subdisks[pd->pd_disk_pos];
1975 disk = vol1->v_subdisks[i].sd_disk;
1996 sd = &vol1->v_subdisks[0];
2084 disk = vol1->v_subdisks[i].sd_disk;
2085 sd = &vol->v_subdisks[i];
2433 sd = &vol->v_subdisks[sdi];
2481 if (vol->v_subdisks[pv->pv_cng_master_disk].sd_state ==
2495 sd = &vol->v_subdisks[sd
[all...]
H A Dmd_jmicron.c694 sd = &vol->v_subdisks[j];
708 sd = &vol->v_subdisks[disk_pos];
1211 sd = &vol->v_subdisks[pd->pd_disk_pos];
1429 sd = &vol->v_subdisks[i];
H A Dmd_ddf.c1432 if (vol->v_subdisks[i].sd_state != G_RAID_SUBDISK_S_NONE)
1677 sd = &vol->v_subdisks[i];
1682 vol->v_subdisks[i].sd_state < sd->sd_state))
1727 sd = &vol->v_subdisks[disk_pos];
1735 vol->v_subdisks[disk_pos].sd_disk = disk;
1809 sd = &vol->v_subdisks[i];
1826 sd = &vol->v_subdisks[i];
1896 sd = &vol->v_subdisks[i];
2485 sd = &vol->v_subdisks[i];
2828 sd = &vol->v_subdisks[
[all...]
H A Dg_raid.h279 struct g_raid_subdisk v_subdisks[G_RAID_MAX_SUBDISKS]; member in struct:g_raid_volume
H A Dmd_nvidia.c704 sd = &vol->v_subdisks[j];
717 sd = &vol->v_subdisks[disk_pos];
1216 sd = &vol->v_subdisks[pd->pd_disk_pos];
1462 sd = &vol->v_subdisks[i];
H A Dmd_sii.c760 sd = &vol->v_subdisks[j];
773 sd = &vol->v_subdisks[disk_pos];
1298 sd = &vol->v_subdisks[pd->pd_disk_pos];
1536 sd = &vol->v_subdisks[i];
H A Dtr_raid5.c284 cbp->bio_caller1 = &vol->v_subdisks[no];

Completed in 132 milliseconds