Searched hist:54979 (Results 1 - 4 of 4) sorted by relevance
/freebsd-10.2-release/sys/dev/mlx/ | ||
H A D | mlxreg.h | diff 54979 Wed Dec 22 01:21:28 MST 1999 msmith Updates resulting from new documentation from Mylex and some cleaning: - Don't keep private copies of some of the data fields from the ENQUIRY and ENQUIRY2 commands. Instead, standardise on the ENQUIRY2 command for initial adapter information, and keep a copy of the entire structure. Refer to it where appropriate. - Move all of the controller description functionality into a new function. Print lots more controller data if bootverbose is set. Add knowledge of the DAC960 PR, PT, PTL0 and PRL controllers, rename the 960PTL -> PTL0 and 1100P -> 1100PVX. - Correctly terminate an error message. The controller interface procedures have been reviewed against the Mylex-supplied documentation; no changes appear necessary at this time. |
H A D | mlx_disk.c | diff 54979 Wed Dec 22 01:21:28 MST 1999 msmith Updates resulting from new documentation from Mylex and some cleaning: - Don't keep private copies of some of the data fields from the ENQUIRY and ENQUIRY2 commands. Instead, standardise on the ENQUIRY2 command for initial adapter information, and keep a copy of the entire structure. Refer to it where appropriate. - Move all of the controller description functionality into a new function. Print lots more controller data if bootverbose is set. Add knowledge of the DAC960 PR, PT, PTL0 and PRL controllers, rename the 960PTL -> PTL0 and 1100P -> 1100PVX. - Correctly terminate an error message. The controller interface procedures have been reviewed against the Mylex-supplied documentation; no changes appear necessary at this time. |
H A D | mlxvar.h | diff 54979 Wed Dec 22 01:21:28 MST 1999 msmith Updates resulting from new documentation from Mylex and some cleaning: - Don't keep private copies of some of the data fields from the ENQUIRY and ENQUIRY2 commands. Instead, standardise on the ENQUIRY2 command for initial adapter information, and keep a copy of the entire structure. Refer to it where appropriate. - Move all of the controller description functionality into a new function. Print lots more controller data if bootverbose is set. Add knowledge of the DAC960 PR, PT, PTL0 and PRL controllers, rename the 960PTL -> PTL0 and 1100P -> 1100PVX. - Correctly terminate an error message. The controller interface procedures have been reviewed against the Mylex-supplied documentation; no changes appear necessary at this time. |
H A D | mlx.c | diff 54979 Wed Dec 22 01:21:28 MST 1999 msmith Updates resulting from new documentation from Mylex and some cleaning: - Don't keep private copies of some of the data fields from the ENQUIRY and ENQUIRY2 commands. Instead, standardise on the ENQUIRY2 command for initial adapter information, and keep a copy of the entire structure. Refer to it where appropriate. - Move all of the controller description functionality into a new function. Print lots more controller data if bootverbose is set. Add knowledge of the DAC960 PR, PT, PTL0 and PRL controllers, rename the 960PTL -> PTL0 and 1100P -> 1100PVX. - Correctly terminate an error message. The controller interface procedures have been reviewed against the Mylex-supplied documentation; no changes appear necessary at this time. |
Completed in 100 milliseconds