Lines Matching refs:data

57     void *data;
58 int (*call)(void *data, int mrq, void *tx_msg, size_t tx_size, void *rx_msg, size_t rx_size);
59 int (*destroy)(void *data);
82 return bpmp->destroy(bpmp->data);
101 return bpmp->call(bpmp->data, mrq, tx_msg, tx_size, rx_msg, rx_size);
123 * The BPMP processes the data and replies with an IVC frame (on the
179 * Minimum size guaranteed for data in an IPC message buffer
446 * @brief Write trace data to a buffer
467 * data from the recipient's local buffer to the output buffer. #area
473 * responsible for protecting its own code and data from accidental
492 * @brief flag whether more data remains in local buffer
533 * The length of data[ ] is unknown to the BPMP core firmware
536 uint8_t data[EMPTY_ARRAY];
546 * The length of data[ ] is unknown to the BPMP core firmware
549 uint8_t data[EMPTY_ARRAY];
572 * written data to a callback provided by the driver. When software on
574 * data to return to the CPU. The intention of the debugfs filesystem
603 /** @brief physical address pointing to data buffer */
605 /** @brief length in bytes of data buffer */
614 /** @brief physical address pointing to data buffer */
616 /** @brief length in bytes of data buffer */
622 * @brief response data for CMD_DEBUGFS_READ/WRITE command
627 /** @brief number of bytes read from or written to data buffer */
633 * @brief response data for CMD_DEBUGFS_DUMPDIR command
638 /** @brief number of bytes read from or written to data buffer */
649 * payload of data.
672 /** @brief response data for CMD_DEBUGFS_READ OR
676 /** @brief response data for CMD_DEBUGFS_DUMPDIR command */
777 * be misaligned. Additionally because #data is variable length, it is
790 /** @brief for write transactions only, #len bytes of data */
791 uint8_t data[];
811 * @brief container for data read from the i2c bus
814 * zero or more I2C reads. The data read from the bus is serialized
820 /** @brief i2c read data */
980 * require no additional data. Others have a sub-command specific
1031 * sub-command-specific data. Some do and some do not as indicated in
1296 * Host->BPMP request data for request type CMD_THERMAL_QUERY_ABI
1305 * Host->BPMP request data for request type CMD_THERMAL_GET_TEMP
1314 * BPMP->Host reply data for request CMD_THERMAL_GET_TEMP
1327 * Host->BPMP request data for request type CMD_THERMAL_SET_TRIP
1342 * BPMP->Host request data for request type CMD_THERMAL_HOST_TRIP_REACHED
1351 * BPMP->Host reply data for request type CMD_THERMAL_GET_NUM_ZONES
1361 * Host->BPMP request data.
1366 * data: Request type specific parameters.
1378 * BPMP->Host request data.
1381 * data: Request type specific parameters.
1402 * @brief Query CPU voltage hint data
1417 * Used by #MRQ_CPU_VHINT call by CCPLEX to retrieve voltage hint data
1425 /** @brief ID of the cluster whose data is requested */
1432 * Used by #MRQ_CPU_VHINT call to carry data pointed by #addr of