3 Hardware that is Known To or Should Work with This Driver
4
5
60. Intro
7
8 This is not an endorsement for hardware vendors (there will be
9 no "where to buy" URLs here with a couple of exception). This

--- 132 unchanged lines hidden (view full) ---

142JMR 4-Bay
143
144 Rinky-tink, but a solid 4 bay loop only entry model.
145
146 I paid 1000$ for mine- overprice, IMO.
147
148JMR Fortra
149
2
3 Hardware that is Known To or Should Work with This Driver
4
5
60. Intro
7
8 This is not an endorsement for hardware vendors (there will be
9 no "where to buy" URLs here with a couple of exception). This

--- 132 unchanged lines hidden (view full) ---

142JMR 4-Bay
143
144 Rinky-tink, but a solid 4 bay loop only entry model.
145
146 I paid 1000$ for mine- overprice, IMO.
147
148JMR Fortra
149
150 I rather like this box. The blue LEDs are a very nice touch- you
150 I rather like this box. The blue LEDs are a very nice touch- you
151 can see them very clearly from 50 feet away.
152
153 I paid 2000$ for one used.
154
155Sun A5X00
156
157 Very expensive (in my opinion) but well crafted. Has two SES
158 instances, so you can use the ses driver (and the example
159 code in /usr/share/examples) for power/thermal/slot monitoring.
160
161 Approx Cost: The last I saw for a price list item on this was 22K$
151 can see them very clearly from 50 feet away.
152
153 I paid 2000$ for one used.
154
155Sun A5X00
156
157 Very expensive (in my opinion) but well crafted. Has two SES
158 instances, so you can use the ses driver (and the example
159 code in /usr/share/examples) for power/thermal/slot monitoring.
160
161 Approx Cost: The last I saw for a price list item on this was 22K$
162 for a unpopulated (no disk drive) A5X00.
162 for an unpopulated (no disk drive) A5X00.
163
164
165DataDirect E1000 RAID
166
167 Don't connect both SCSI and FC interfaces at the same time- a SCSI
168 reset will cause the DataDirect to think you want to use the SCSI
169 interface and a LIP on the FC interface will cause it to think you
170 want to use the FC interface. Use only one connector at a time so
171 both you and the DataDirect are sure about what you want.
172
173 Cost: I have no idea.
174
175Veritas ServPoint
176
177 This is a software storage virtualization engine that
163
164
165DataDirect E1000 RAID
166
167 Don't connect both SCSI and FC interfaces at the same time- a SCSI
168 reset will cause the DataDirect to think you want to use the SCSI
169 interface and a LIP on the FC interface will cause it to think you
170 want to use the FC interface. Use only one connector at a time so
171 both you and the DataDirect are sure about what you want.
172
173 Cost: I have no idea.
174
175Veritas ServPoint
176
177 This is a software storage virtualization engine that
178 runs on Sparc/Solaris in target mode for frontend
178 runs on Sparc/Solaris in target mode for frontend
179 and with other FC or SCSI as the backend storage. FreeBSD
180 has been used extensively to test it.
181
182
183 Cost: I have no idea.
184
1856. Disk Drives
186

--- 118 unchanged lines hidden ---
179 and with other FC or SCSI as the backend storage. FreeBSD
180 has been used extensively to test it.
181
182
183 Cost: I have no idea.
184
1856. Disk Drives